Interface Solutions: This is a guide to using the E2S Intrinsically safe sounders and beacons, it is based on the Atex certification but in general the guidelines apply to other intrinsic safety certifications including North American FM and IECEx. |
| Intrinsic Safety is a protection technique based upon the restriction of electrical energy to a level below that which can cause ignition by either sparking of heating effects. It is a system concept; unlike most other hazardous area protection methods, such as flameproof Ex d, all items in an intrinsically safe circuit must be taken into consideration. An Intrinsically safe circuit is typically defined as: "A circuit in which any spark or thermal effect produced in normal operation and specified fault conditions is not capable of causing ignition" So the preservation of intrinsic safety depends on the strict control of energy in the circuit and therefore the whole circuit needs to be considered, not just the field apparatus in isolation. |
![]() |
Associated apparatus is the name given to the piece of equipment which is responsible for controlling the level of voltage and current which will be permitted to enter the intrinsically safe circuit within the hazardous area. |
Additional certification (Ex N) for the associated apparatus may be utilised e.g. many zener barriers are approved to Ex N which allows the interface to be installed in a Zone 2 hazardous areas with appropriate enclosure. In this case in the context of the intrinsically safe circuit it is assumed the interface is in the safe area. |
Cables have also to be taken in to consideration. Interconnecting cables include reactance which will have an effect on the storage of energy in the circuit. The calculation of cable requirements is out with the scope of this document. However, as intrinsic safety is low power, and is usually installed with small diameter cabling cable runs are rarely an issue. For more information on this please contact E2S |
| IP Rating for an intrinsically safe installation is on IP20. However in practice a higher IP rating is usually required to meet environmental conditions or site standards. |
|
|
Products: |
| E2S part codes: View product information, listed by item code. |
| Press Release Review current and archive press information. |
| Alarm tones: Listen to & download 45 of the frequencies available. |
| Contact E2S: Request a catalogue or further information |
|
|
|
|
|
Products
Menu: Product data & manuals. |
|
Alarm tones:
Listen to the E2S alarm tone frequencies. |
|
Ordering info: How & where to buy. |
|
|