IS-AL105NL Intrinsically Safe Combined Signal 1-13-020

Product image
Product Image
Product Image
Intrinsically Safe combination L.E.D beacon/light & alarm horn.
Request a quote for this product
Enclosure Color
LED Color
Part Number:
IS-AL105NL-
Request Price or enquire about this product
Enquire about
Intrinsically Safe Combined Signal

Description

The IS-A105N+IS-L101L unit is an intrinsically safe field mounting combined alarm horn with L.E.D. beacon/light which provides a a loud audible and bright flashing visual signal utilising a common Zener barrier or galvanic isolator. The alarm horn features an alarm accept function – by closing a pair of external contacts (i.e push switch) the operator may silence the alarm for set periods between 5 seconds and 2 hours. If after the pre-set time the alarm condition still exists the sounder will activate again. Certified for use in application requiring Ex ia or Class I Div 1 equipment the IS-A105N+IS-L101L is a globally accepted solution to fire or process control signalling.

Downloads

Features

  • Input overload and reverse current protection
  • Prismatic lens optimises L.E.D effectiveness
  • Auto synchronised sound output
  • Unit can be mounted using external lugs or internal BESA compatible fixing positions.
  • Duplicate cable terminations
    (in & out for daisy-chain installations).
  • Available with custom tone configurations
    and frequencies.

Specification

Sounder/horn:
Nominal output: 105dB(A) @ 1m +/- 3dB – Tone 2* [96dB(A) @ 10ft/3m]
No. of tones: 49 (UKOOA/PFEER compliant)
No. of stages: 3
Volume control: Max. 105dB(A);
Min. 96dB(A) – Tone 2
Effective range: 60m/197ft @ 1KHz
Beacon/light:
Light source: Array of 6 high intensity L.E.D’s
L.E.D. colours: Red, Amber, Blue, Green & White
Note: Blue, Green & White LED versions utilise a Clear lens
Standalone mode: 2Hz (2 double flashes per second)
Effective intensity cd: 48cd* – measured ref. to I.E.S.
Flash rate: On: 1 Hz (1 double flash per second
Silenced: 2 Hz (2 double flashes per second – alarm accepted)
General:
Voltage: 16-28vdc via Zener barrier or galvanic isolator
Current: 25mA typical when powered from 24v
supply via 28v 300 Ohm Zener barrier
Ingress protection: IP66
Rating: Continuous
Enclosure material: UL94V0 & 5VA FR ABS
Enclosure colour: RAL3000 Red, Grey RAL7038
Fixings: Stainless Steel
Cable entries: 2 x M20 entries – stopping plugs included
Terminals: 0.5 to 2.5mm²
Operating temp: -40° to +60°C [-40° to +140°F]
Storage temp: -40° to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: 1.15kg/2.53Ibs
*SPL data +/-3dB(A). Measured at optimum voltage.

Part Codes

IS-AL105NL-[x]/[y]
[x]: Enclosure colour: Red RAL3000
Grey RAL7038
[y]: Lens/LED colour: A: Amber
B: Blue
G: Green
R: Red
C: Clear (White LED)
Note: Note: Blue, Green & White LED versions utilise a Clear lens
May be powered from any certified Zener barrier or, galvanic isolator whose output parameters do not exceed:
Uo : 28VDC Io : 93mA Po : 1.2W

Approvals

  • ATEX certificate: SIRA 04ATEX2301X
  • IECEx certificate: IECEx SIR 04.0038X
  • FM approved:
  • Ex EAC certificate: POCC GB.JB05.B03365

Coding

ATEX / IECEx / FM:
II 1G Ex ia IIC T4 Ga (-40ºC <=Ta<= +60°C)
IS Class I, Zone 0, AEx ia IIC T4 Ta = +60°C
IS Class l, Division 1, Groups A, B, C, D T4
Ex EAC:
0ExiaIICT4 IP65 -40° to +60°C

Tone Table

Stage 1 WAV file Frequency Description. Stg 2 Stg 3
T 1 /system/1/assets/files/000/000/415/415/246615edd/original/TF001.WAV 340 Hz Continuous T 2 T 5
T 2 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 800/1000Hz @ 0.25 sec Alternating T 17 T 5
T 3 /system/1/assets/files/000/000/417/417/abf396de0/original/TF003.WAV 500/1200Hz @ 0.3Hz 0.5 sec Slow Whoop T 2 T 5
T 4 /system/1/assets/files/000/000/420/420/50f9ee7a7/original/TF004.WAV 800/1000Hz @ 1Hz Sweeping T 6 T 5
T 5 /system/1/assets/files/000/000/421/421/b578af8a9/original/TF005.WAV 2400Hz Continuous T 3 T 20
T 6 /system/1/assets/files/000/000/422/422/42b72dd93/original/TF006.WAV 2400/2900Hz @ 7Hz Sweeping T 7 T 5
T 7 /system/1/assets/files/000/000/373/373/a686b0abe/original/TF007.WAV 2400/2900Hz @ 1Hz Sweeping T 10 T 5
T 8 /system/1/assets/files/000/000/376/376/00cd26f9e/original/TF008.WAV 500/1200/500Hz @ 0.3Hz Sweeping T 2 T 5
T 9 /system/1/assets/files/000/000/386/386/ceb4e488c/original/TF009.WAV 1200/500Hz @ 1Hz – DIN / PFEER P.T.A.P. T 15 T 2
T 10 /system/1/assets/files/000/000/374/374/021ee6540/original/TF010.WAV 2400/2900Hz @ 2Hz Alternating T 7 T 5
T 11 /system/1/assets/files/000/000/377/377/ac5498db0/original/TF011.WAV 1000Hz @ 1Hz Intermittent T 2 T 5
T 12 /system/1/assets/files/000/000/375/375/771bd7a3e/original/TF012.WAV 800/1000Hz @ 0.875Hz Alternating T 4 T 5
T 13 /system/1/assets/files/000/000/378/378/6380218ec/original/TF013.WAV 2400Hz @ 1Hz Intermittent T 15 T 5
T 14 /system/1/assets/files/000/000/379/379/51c1bb5a9/original/TF014.WAV 800Hz 0.25sec on, 1 sec off Intermittent T 4 T 5
T 15 /system/1/assets/files/000/000/380/380/06feaa7b3/original/TF015.WAV 800Hz Continuous T 2 T 5
T 16 /system/1/assets/files/000/000/381/381/93f51c79a/original/TF016.WAV 660Hz 150mS on, 150mS off Intermittent T 18 T 5
T 17 /system/1/assets/files/000/000/382/382/2c2978b6a/original/TF017.WAV 544Hz (100mS)/440Hz (400mS) – NF S 32-001 T 2 T 27
T 18 /system/1/assets/files/000/000/397/397/d6d84d0c3/original/TF018.WAV 660Hz 1.8sec on, 1.8sec off Intermittent T 2 T 5
T 19 /system/1/assets/files/000/000/383/383/11797b764/original/TF019.WAV 1.4KHz-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s -NFC48-265 T 2 T 5
T 20 /system/1/assets/files/000/000/384/384/5c30f9f4d/original/TF020.WAV 660Hz Continuous T 2 T 5
T 21 /system/1/assets/files/000/000/385/385/a85a0a356/original/TF021.WAV 554Hz/440Hz @ 1Hz Alternating T 2 T 5
T 22 /system/1/assets/files/000/000/387/387/d33e565a9/original/TF022.WAV 544Hz @ 0.875 sec. Intermittent T 2 T 5
T 23 /system/1/assets/files/000/000/388/388/b4cf9203e/original/TF023.WAV 800Hz @ 2Hz Intermittent T 6 T 5
T 24 /system/1/assets/files/000/000/389/389/68683d240/original/TF024.WAV 800/1000Hz @ 50Hz Sweeping T 29 T 5
T 25 /system/1/assets/files/000/000/398/398/7c1bf5e00/original/TF025.WAV 2400/2900Hz @ 50Hz Sweeping T 29 T 5
T 26 /system/1/assets/files/000/000/395/395/631e82dc8/original/TF026.WAV Bell T 2 T 15
T 27 /system/1/assets/files/000/000/390/390/10abe0caa/original/TF027.WAV 554Hz Continuous T 26 T 5
T 28 /system/1/assets/files/000/000/391/391/5f7a58b54/original/TF028.WAV 440Hz Continuous T 2 T 5
T 29 /system/1/assets/files/000/000/392/392/68d5d1294/original/TF029.WAV 800/1000Hz @ 7Hz Sweeping T 7 T 5
T 30 /system/1/assets/files/000/000/393/393/744c6f53f/original/TF030.WAV 300Hz Continuous T 2 T 5
T 31 /system/1/assets/files/000/000/394/394/1bfee2f1b/original/TF031.WAV 660/1200Hz @ 1Hz Sweeping T 26 T 5
T 32 /system/1/assets/files/000/000/396/396/d64fbc9d0/original/TF032.WAV Two T chime. T 26 T 15
T 33 /system/1/assets/files/000/000/410/410/a0f0ba2a6/original/TF033.WAV 745Hz @ 1Hz Intermittent T 2 T 5
T 34 /system/1/assets/files/000/000/399/399/84b54dafb/original/TF034.WAV 1000 & 2000Hz @ 0.5 sec Alternating – Singapore T 38 T 45
T 35 /system/1/assets/files/000/000/402/402/9168c8c48/original/TF035.WAV 420Hz @ 0.625 sec Australian Alert T 36 T 5
T 36 /system/1/assets/files/000/000/400/400/aba6c8a51/original/TF036.WAV 500-1200Hz 3.75sec /0.25sec. Australian Evac. T 35 T 5
T 37 /system/1/assets/files/000/000/405/405/214ccf82a/original/TF037.WAV 1000Hz Continuous – PFEER Toxic Gas T 9 T 45
T 38 /system/1/assets/files/000/000/407/407/ecce63f4f/original/TF038.WAV 2000Hz Continuous T 34 T 45
T 39 /system/1/assets/files/000/000/401/401/e3954ab10/original/TF039.WAV 800Hz 0.25sec on, 1 sec off Intermittent T 23 T 17
T 40 /system/1/assets/files/000/000/403/403/88b145b84/original/TF040.WAV 544Hz (100mS)/440Hz (400mS) – NF S 32-001 T 31 T 27
T 41 /system/1/assets/files/000/000/404/404/1c1741943/original/TF041.WAV Motor Siren – slow rise to 1200 Hz T 2 T 5
T 42 /system/1/assets/files/000/000/408/408/e0fadcdd2/original/TF042.WAV Motor Siren – slow rise to 800 Hz T 2 T 5
T 43 /system/1/assets/files/000/000/406/406/49b88184e/original/TF043.WAV 1200 Hz Continuous T 2 T 5
T 44 /system/1/assets/files/000/000/409/409/590aa5e82/original/TF044.WAV Motor Siren – slow rise to 2400 Hz T 2 T 5
T 45 /system/1/assets/files/000/000/412/412/fa8b418f9/original/TF045.WAV 1KHz 1s on, 1s off Intermittent – PFEER Gen. Alarm T 38 T 34
T 46 /system/1/assets/files/000/000/386/386/ceb4e488c/original/TF009.WAV 1200/500Hz @ 1Hz – DIN / PFEER P.T.A.P. T 47 T 37
T 47 /system/1/assets/files/000/000/412/412/fa8b418f9/original/TF045.WAV 1KHz 1s on, 1s off Intermittent – PFEER Gen. Alarm T 46 T 37
T 48 /system/1/assets/files/000/000/402/402/9168c8c48/original/TF035.WAV 420Hz @ 0.625 sec Australian Alert T 49 T 5
T 49 /system/1/assets/files/000/000/400/400/aba6c8a51/original/TF036.WAV 500-1200Hz 3.75sec /0.25sec. Australian Evac. T 26 T 37
Country specific or custom tone configurations and alarm frequencies are available upon request.