Product finder
Product code
Application
Environment
Device
Category
Product
Type
Product finder

Find the right E2S product

Search

GNExS1R Alarm Horn Sounder 1-22-030

Product Image
Product Image
The GNExS1R is an IECEx and ATEX certified alarm horn sounder with a compact, omni-directional horn. The robust GRP (glass reinforced polyester) enclosure is approved for Zone 1 & Zone 2 explosion proof signalling applications.
Request a quote for this product
Voltage
Cable entries
Stopping plug/adaptor material
Bracket material
Product version
Product option
Enclosure colour
Part Number:
GNExS1R
Request Price or enquire about this product
Enquire about
Alarm Horn Sounder

Upgraded Product

  • New D Class amplifier technology
  • Reduced in-rush
  • A4 316 stainless steel bracket as standard
  • Tropicalised electronics
  • New stage activation and line monitoring capability

Description

Featuring 64 alarm tone sounds, each of the available 4 stage/channels can be remotely triggered. Class D amplification provides a high sound output at optimum an operating current. The threaded flameproof joint, multiple cable entries and duplicated, pluggable termination simplifies both installation and routine maintenance. SIL1 & SIL2 Route 2H compliant to IEC61508 (2010) as standard.

Downloads

Datasheet Datasheet.pdf
Install manual: Product version [A] D157-01-001-IS_Issue_5__GNExS1_.pdf
Install manual: Product version [S] D157-01-651-IS_Issue_2__GNExS1-S_.pdf
-Install manual Telephone-Relay version [T] D157-01-681-IS_Issue_1__GNExS1-T_.pdf
Installation Manual - Russian D157-00-001-IS-RUS_Issue_6_GNExS1.pdf
INMETRO Installation Manual D157-00-001-IS-IEx_Issue_B.pdf
IECEx certificate IECEx_SIR_13.0029X_Issue_1_GNExS_L.pdf
ATEX certificate Sira_13ATEX1139X_Issue_2_GNExS_L.pdf
UKCA Certificate CSAE_21UKEX1558X_Iss_0_GNExS___L.pdf
INMETRO certificate IEx20.0050X_R1_GNExS_GNExL.pdf
Russian Ex certificate EAC_EU_C-GB.AA71.B.00273_20.pdf
Russian Fire certificate EAC043-RU_C-GB.68.B.00881-22__GNExS_BExS110_.pdf
ECAS Ex Approval ECAS_23-08-81407_E23-07-082141_NB0007_GNExS-L.pdf
Ingress Protection certificate CoTC_104611_Issue_2_GNExS-L-B-J.pdf
Declaration of Conformity DC-038_Issue_F_GNExS_GNExL.pdf
Declaration of Conformity UKCA DC-095_Issue_A_GNExS__GNExL_UKCA.pdf
SIL Certificate: Product version [A] T1072-215-2_SIL2_SIL1_2H__D1xS_D1xC_STExS_STExC_GNExS_A112N_AL112N_A121_AL121_MA_.pdf
2D drawing (PDF) D157-05-051_Issue_2.pdf
2D drawing (DWG) D157-05-051_Issue_2.DWG
3D drawing (STEP) D157-05-051-3D_Issue_B_GNExS1R_.STEP
Wiring Schematic DC voltage D190-06-001_Issue_1_GNExS_DC_.pdf
Wiring Schematic AC voltage D190-06-005_Issue_1_GNExS_AC_.pdf
Nameplate Drawing D157-09-001_Issue_1_GNExS_.pdf
Equipment Tag Drawing D254-00-101_Issue_1.pdf
Duty Label Drawing D254-00-001_Issue_1.pdf
Pole Mount & Sun Shade Drawing D217-05-024_Issue_1__GNExS1R_.pdf

Features

  • Maximum sound pressure level output of 113dB(A)
  • Choice of 64 alarm tone frequencies
  • 4 remotely selectable alarm stages/channels
  • Positive or negative line stage/channel switching
  • Automatic synchronisation on multi-sounder system
  • Ratchet adjustable 316 stainless steel bracket
  • Triple cable entries
  • Available with custom tone configurations and frequencies
  • Robust corrosion proof GRP (glass reinforced polyester) enclosure

Specification

Maximum output: 110dB(A) @ 1 m +/- 3dB [101dB(A) @ 10ft/3m +/- 3dB]
Nominal output: 105dB(A) @ 1m +/- 3dB [96dB(A) @ 10ft/3m] +/- 3dB
No. of tones: 45 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Full range
Effective range: 125m/410ft @ 1KHz
Voltages DC: 24Vdc (10-30vdc), 48vdc (38-60Vdc)
Voltages AC: 230Vac (100-260Vac)
In-rush: 815mA within 4ms @ 24Vdc
Stage switching: DC units: positive or negative
AC units: common supply line
Safety Integrity Level: SIL1 and SIL2 Route 2H IEC61508 (2010)
Ingress protection: EN60529: IP66
Enclosure material: UV stable GRP (glass reinforced polyester)
Enclosure colour: Natural Red
Enclosure finish: Natural – can be painted in alternative colours
Cable entries: 2 x M20x1.5mm
Stopping plug included
Stopping plugs: Brass, Nickel Plated or Stainless Steel
Terminals: 0.5 – 2.5mm² (20-14 AWG)
Pluggable & duplicated terminals
Line monitoring: Diode polarized for use in supervised circuits
Blocking diode for reverse polarity monitoring
Ground/Earth stud: M4
Line monitoring: Blocking diode included
EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor
or diode (DC versions) can be fitted
Enclosure volume: <2 litres
Installation temp: -50° to +70°C (-58°F to +158°F)
Storage temp: -50° to +70°C (-58°F to +158°F)
Relative humidity: 99%
MTBF DC: 93.92 years / 822,706 hours – MIL 217
MTBF AC: 46.66 years / 408,508 hours – MIL 217
Weight: DC: 3.00kg/6.6Ibs AC: 3.20kg/7.04Ibs

Current Consumption

Nominal
Voltage:
Voltage
range:
Nominal
current:
Max.
current:
In-rush:
12Vdc 10-30Vdc 221mA 221mA -
24Vdc 10-30Vdc 185mA 221mA 815mA <4ms
48Vdc 38-60Vdc 115mA 221mA -
115Vac 50/60Hz 100-260V ac 73mA 80mA -
230Vac 50/60Hz 100-260V ac 48mA 80mA -

Part Codes

Part Code: Identifier: Description:
Product type: GNExS1 GNExS1 alarm horn sounder
Horn type: R Radial omni-directional horn
Voltage: DC024
DC048
AC230
10-30Vdc
38-60Vdc
100-260Vac
Cable entries:[e] A
B
C
D
E
F
G
2 x M20x1.5mm
2 × 1/2" NPT – adaptors
2 × 3/4" NPT – adaptors
2 x M25x1.5mm – adaptors
1 × 1/2" NPT – adaptor
1 × 3/4" NPT – adaptor
1 x M25x1.5mm – adaptor
Stopping plug/
adaptor material: [m]
B
N
S
Brass
Nickel plated brass
Stainless steel
Bracket material: [s] 1
3
A4 316 Stainless Steel
A4 316 St/St with Equip. Tag
Product version: [v] A
S

T
IECEx, ATEX, Ex EAC, INMETRO – SIL1 & SIL2 Route 2H
IECEx, ATEX, Ex EAC, INMETRO – SIL2
Route 1H with diagnostics SFF: >99%
IECEx, ATEX, Ex EAC, INMETRO – Telephone/Relay initiate
Product option: [o] 1
Z
X
Y
K
V
Standard product
Custom alarm tone software – contact E2S
Custom configuration – contact E2S
Stage control Config. 4
Stage control Config. 5 (DC) and Config. 2 (AC)
Stage control Config. 6
Enclosure colour: [x] R
S
Red
Special – contact E2S for alternative enclosure colours
Accessories:
SP65-0001-A4
SP65-0003-A4
Pole Mount Bracket Kit St/St A4 (316)
Sunshade – St/St A4 (316)
Alarm stage control:
Please review the installation manual and wiring schematics for remote stage control and EOL resistor monitoring configuration options:
Config. 1 [DC]: Factory default. Common negative, positive switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 2 [DC]: User setting. Common positive, negative switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 3 [DC]: User setting. Common negative, positive switching activation of Alarm Stages 1 & 2 with EOL on both stages. Reverse polarity monitoring
Config. 4 [DC]: Product option ‘Y’. Independent activation of Alarm Stages 1 & 2 with EOL on both stages. Forward polarity monitoring
Config. 5 [DC]: Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages
Config. 6 [DC]: Product option ‘V’. Independent activation of up to 4 Alarm Stages with EOL on all stages. Forward polarity monitoring
Config. 1 [AC]: Factory default. Up to 4 Alarm Stages. Stage 1 activated at power on. Stages 2, 3 and 4 via volt free contacts
Config. 2 [AC]: Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages

Approvals

  • ATEX certificate: SIRA 13ATEX1139X
  • IECEx certificate: IECEx SIR 13.0029X
  • Ex EAC TR CU 012/2011 certified: KZ.1510019.22.01.00271
  • INMETRO IEx 20.0050X
  • SIL1 & SIL2 compliant to IEC61508 (2010)

Assemblies

The GNExS1R is available as a plated assembly configured with Xenon strobe or LED beacons with or without a GNExJ2 Ex d junction box.
Contact E2S for further information.

Coding

  • IECEx / ATEX
    II 2G Ex d IIC T4 Ta. -60°C to +50°C
    II 2G Ex d IIC T3 Ta. -60°C to +70°C
    II 2G Ex d IIB T6 Ta. -60°C to +50°C
    II 2G Ex d IIB T5 Ta. -60°C to +65°C
    II 2G Ex d IIB T4 Ta. -60°C to +70°C

Tone Table

Stage 1 WAV file Frequency Description. Stage 2 Stage 3 Stage 4
T 1 /system/1/assets/files/000/000/405/405/214ccf82a/original/TF037.WAV 1000 Continuous – PFEER Toxic Gas Any T 2 T 44
T 2 /system/1/assets/files/000/000/386/386/ceb4e488c/original/TF009.WAV 1200/500 @ 1Hz Sweeping – DIN / PFEER P.T.A.P. Any T 3 T 44
T 3 /system/1/assets/files/000/000/412/412/fa8b418f9/original/TF045.WAV 1000 @ 0.5Hz (1s on, 1s off) Intermittent – PFEER Gen. Alarm Any T 2 T 44
T 4 /system/1/assets/files/000/000/383/383/11797b764/original/TF019.WAV 1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s – NF C 48-265 Any T 24 T 1
T 5 /system/1/assets/files/000/000/382/382/2c2978b6a/original/TF017.WAV 544(100mS)/440 (400mS) – NF S 32-001 Any T 19 T 1
T 6 /system/1/assets/files/000/000/947/947/8f040484a/original/TF053.wav 1500/500 – (0.5s on , 0.5s off) x3 + 1s gap – AS4428 Any T 44 T 1
T 7 /system/1/assets/files/000/000/944/944/890010fd0/original/TF054.wav 500-1500Hz Sweeping 2 sec on 1 sec off – AS4428 Any T 44 T 1
T 8 /system/1/assets/files/000/000/417/417/abf396de0/original/TF003.WAV 500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) – NEN 2575 Any T 24 T 35
T 9 /system/1/assets/files/000/000/953/953/5deedc543/original/TF055.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 10 /system/1/assets/files/000/000/952/952/3a041fde3/original/TF056.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 11 /system/1/assets/files/000/000/946/946/761de34c6/original/TF057.wav 420(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal Any T 1 T 8
T 12 /system/1/assets/files/000/000/945/945/689d9405a/original/TF058.wav 1000(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal Any T 1 T 8
T 13 /system/1/assets/files/000/000/950/950/2d337d14e/original/TF059.wav 422/775 – (0.85 on, 0.5 off) x3 + 1s gap – NFPA Temporal Any T 1 T 8
T 14 /system/1/assets/files/000/000/399/399/84b54dafb/original/TF034.WAV 1000/2000 @ 1Hz – Singapore Any T 3 T 35
T 15 /system/1/assets/files/000/000/393/393/744c6f53f/original/TF030.WAV 300 Continuous Any T 24 T 35
T 16 /system/1/assets/files/000/000/391/391/5f7a58b54/original/TF028.WAV 440 Continuous Any T 24 T 35
T 17 /system/1/assets/files/000/000/948/948/c697b364a/original/TF060.wav 470 Continuous Any T 24 T 35
T 18 /system/1/assets/files/000/000/949/949/7e429e658/original/TF061.wav 500 Continuous – IMO code 2 (Low) Any T 24 T 35
T 19 /system/1/assets/files/000/000/390/390/10abe0caa/original/TF027.WAV 554 Continuous Any T 24 T 35
T 20 /system/1/assets/files/000/000/384/384/5c30f9f4d/original/TF020.WAV 660 Continuous Any T 24 T 35
T 21 /system/1/assets/files/000/000/380/380/06feaa7b3/original/TF015.WAV 800 Continuous – IMO code 2 (High) Any T 24 T 35
T 22 /system/1/assets/files/000/000/406/406/49b88184e/original/TF043.WAV 1200 Continuous Any T 24 T 35
T 23 /system/1/assets/files/000/000/407/407/ecce63f4f/original/TF038.WAV 2000 Continuous Any T 3 T 35
T 24 /system/1/assets/files/000/000/421/421/b578af8a9/original/TF005.WAV 2400 Continuous Any T 20 T 35
T 25 /system/1/assets/files/000/000/951/951/d9ce2b2c6/original/TF062.wav 440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent Any T 44 T 8
T 26 /system/1/assets/files/000/000/954/954/b703d99f1/original/TF063.wav 470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent Any T 44 T 8
T 27 /system/1/assets/files/000/000/955/955/0f602886a/original/TF064.wav 470 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T 44 T 8
T 28 /system/1/assets/files/000/000/956/956/dbb5f64db/original/TF065.wav 544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent Any T 24 T 8
T 29 /system/1/assets/files/000/000/957/957/7bd3d8c1c/original/TF066.wav 655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent Any T 44 T 8
T 30 /system/1/assets/files/000/000/397/397/d6d84d0c3/original/TF018.WAV 660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent Any T 24 T 8
T 31 /system/1/assets/files/000/000/381/381/93f51c79a/original/TF016.WAV 660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent Any T 24 T 8
T 32 /system/1/assets/files/000/000/410/410/a0f0ba2a6/original/TF033.WAV 745 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 33 /system/1/assets/files/000/000/379/379/51c1bb5a9/original/TF014.WAV 800 (0.25s on, 1.00s off) Intermittent Any T 24 T 8
T 34 /system/1/assets/files/000/000/388/388/b4cf9203e/original/TF023.WAV 800 @ 2Hz (0.25s on, 0.25s off) – IMO code 3.a (High) Any T 24 T 8
T 35 /system/1/assets/files/000/000/377/377/ac5498db0/original/TF011.WAV 1000 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 36 /system/1/assets/files/000/000/378/378/6380218ec/original/TF013.WAV 2400 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 37 /system/1/assets/files/000/000/958/958/a90e62da4/original/TF067.wav 2900 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T 24 T 8
T 38 /system/1/assets/files/000/000/959/959/f34b52faa/original/TF068.wav 363/518 @ 1Hz (0.50s / 0.50s) Alternating Any T 8 T 19
T 39 /system/1/assets/files/000/000/960/960/368703340/original/TF069.wav 450/500 @ 2Hz (0.25s / 0.25s) Alternating Any T 8 T 19
T 40 /system/1/assets/files/000/000/385/385/a85a0a356/original/TF021.WAV 554/440 @ 1Hz (0.50s / 0.50s) Alternating Any T 24 T 19
T 41 /system/1/assets/files/000/000/961/961/be2680966/original/TF070.wav 554/440 @ 0.65Hz (0.76s / 0.76s) Alternating Any T 8 T 19
T 42 /system/1/assets/files/000/000/962/962/314fe8a1b/original/TF071.wav 561/760 @ 0.83Hz (0.60s / 0.60s) Alternating Any T 8 T 19
T 43 /system/1/assets/files/000/000/963/963/5f6deb8a1/original/TF072.wav 780/600 @ 0.96Hz (0.52s / 0.52s) Alternating Any T 8 T 19
T 44 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 800/1000 @ 2Hz (0.25s / 0.25s) Alternating Any T 24 T 19
T 45 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 970/800 @ 2Hz (0.25s / 0.25s) Alternating Any T 8 T 19
T 46 /system/1/assets/files/000/000/375/375/771bd7a3e/original/TF012.WAV 800/1000 @ 0.875Hz (0.57s / 0.57s) Alternating Any T 24 T 19
T 47 /system/1/assets/files/000/000/374/374/021ee6540/original/TF010.WAV 2400/2900 @ 2Hz (0.25s / 0.25s) Alternating Any T 24 T 19
T 48 /system/1/assets/files/000/000/965/965/e3d76c24c/original/TF073.wav 500/1200 @ 0.3Hz (1.67s / 1.67s) Sweeping Any T 24 T 12
T 49 /system/1/assets/files/000/000/964/964/4e1cd3f7f/original/TF074.wav 560/1055 @ 0.18Hz (2.73s / 2.73s) Sweeping Any T 24 T 12
T 50 /system/1/assets/files/000/000/966/966/a8e5f4440/original/TF075.wav 560/1055 @ 3.3Hz (0.15s / 0.15s) Sweeping Any T 24 T 12
T 51 /system/1/assets/files/000/000/969/969/5734194b1/original/TF076.wav 600/1250 @ 0.125Hz (4s / 4s) Sweeping Any T 24 T 12
T 52 /system/1/assets/files/000/000/394/394/1bfee2f1b/original/TF031.WAV 660/1200 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 53 /system/1/assets/files/000/000/420/420/50f9ee7a7/original/TF004.WAV 800/1000 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 54 /system/1/assets/files/000/000/392/392/68d5d1294/original/TF029.WAV 800/1000 @ 7Hz (0.07s / 0.07s) Sweeping Any T 24 T 12
T 55 /system/1/assets/files/000/000/389/389/68683d240/original/TF024.WAV 800/1000 @ 50Hz (0.01s / 0.01s) Sweeping Any T 24 T 12
T 56 /system/1/assets/files/000/000/422/422/42b72dd93/original/TF006.WAV 2400/2900 @ 7Hz (0.07s / 0.07s) Sweeping Any T 24 T 12
T 57 /system/1/assets/files/000/000/373/373/a686b0abe/original/TF007.WAV 2400/2900 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 58 /system/1/assets/files/000/000/398/398/7c1bf5e00/original/TF025.WAV 2400/2900 @ 50Hz (0.01s / 0.01s) Sweeping Any T 24 T 12
T 59 /system/1/assets/files/000/000/967/967/2e92dbc46/original/TF077.wav 2500/3000 @ 2Hz (0.25s / 0.25s) Sweeping Any T 24 T 12
T 60 /system/1/assets/files/000/000/968/968/5dfcb9aea/original/TF078.wav 2500/3000 @ 7.7Hz (0.65s / 0.65s) Sweeping Any T 24 T 12
T 61 /system/1/assets/files/000/000/408/408/e0fadcdd2/original/TF042.WAV 800Hz Motor Siren Any T 24 T 12
T 62 /system/1/assets/files/000/000/404/404/1c1741943/original/TF041.WAV 1200Hz Motor Siren Any T 24 T 12
T 63 /system/1/assets/files/000/000/409/409/590aa5e82/original/TF044.WAV 2400Hz Motor Siren Any T 24 T 12
T 64 /system/1/assets/files/000/000/395/395/631e82dc8/original/TF026.WAV Simulated Bell Any T 21 T 12
For Stage 2 any Stage 1 alarm tone sound can be selected.
Country specific or custom tone configurations and alarm frequencies are available upon request.

Upcoming Events

Fse (4)
Cafaa%202020%20final%20cmyk
Logo
Nfpa conference expo