D1xC2X05R 114dB(A) Radial Alarm & 5J Xenon Strobe 1-23-075

Product Image
Product Image
Product Image
The D1xC2X05R is a globally certified alarm horn sounder with a compact, omni-directional horn and combined with a 5 Joule Xenon strobe beacon. The robust Type 4/4X, IP66 marine grade, corrosion proof aluminium enclosure is approved for Class I & II Div 1, Zone 1 & 20, IECEx and ATEx Zone 1, 2, 21 & 22 explosion proof signalling applications.
Request a quote for this product
Voltage
Cable entries
Stopping plug/adaptor material
Bracket/Guard material
Product version
Product option
Enclosure colour
Lens colour
Part Number:
D1xC2X05R
Request Price or enquire about this product
Enquire about
114dB(A) Radial Alarm & 5J Xenon Strobe

Upgraded Product

  • New IECEx & ATEX approval
  • New D Class amplifier technology
  • Reduced in-rush
  • A4 316 stainless steel bracket and guard as standard
  • New stage activation and line monitoring capability

Description

Featuring 64 alarm tones, each of the 4 stage/channels can be remotely activated. Class D amplification provides a high sound output with a choice of two power modes. The threaded flameproof joint, multiple cable entries and duplicated, pluggable termination simplifies both installation and routine maintenance. The 24Vdc Class I version is approved for public (alarm horn) and private mode fire alarm use (strobe beacon). SIL1 & SIL2 Route 2H compliant to IEC61508 (2010) as standard.

Downloads

Datasheet Datasheet.pdf
Install manual: Product version [A] D190-01-301-IS_Issue_6__D1xC_.pdf
Install manual: Product version [D] D190-00-361-IS-SC_Issue_3_D1xC-R_DUST.pdf
IECEx certificate IECEx_ULD_19.0008X_002_D1xC_S_L.pdf
ATEX certificate DEMKO_19_ATEX_2141X_Issue_2_D1xC_S_L.pdf
UL certificate of compliance UL_CoC_20150818-E230764_Vol1Sec3__D1xS-C_.pdf
CSFM Listing CSFM_Listing_2279-0506_D1xS__D1xC_2025.pdf
UKCA Certificate UL21UKE2132X_Rev1_D1xC_S_L.pdf
CCOE PESO COOE_P576154_D1xS_D1xC_D1xL.pdf
ECAS Ex Approval 24-06-114451_E24-06-118027_NB0007_D1xS-L.pdf
Ingress Protection certificate TL23065B_E2S_IP66_and_IPX7.pdf
Declaration of Conformity DC-067_Issue_K_D1x.pdf
Declaration of Conformity UKCA DC-097_Issue_A__D1x_UKCA_.pdf
SIL Certificate: Product version [A] T1072-215-2_SIL2_SIL1_2H__D1xS_D1xC_STExS_STExC_GNExS_A112N_AL112N_A121_AL121_MA_.pdf
2D drawing (PDF) D190-05-321_Issue_D.pdf
2D drawing (DWG) D190-05-321_Issue_D.dwg
Outline STEP drawing with U bracket D190-05-321-3D_Issue_1.STEP
Outline STEP drawing with surface bracket D190-05-321-Alt-3D_Issue_2.STEP
Wiring Schematic DC voltage D190-06-301_Issue_4.pdf
Wiring Schematic AC voltage D190-06-305_Issue_1.pdf
Nameplate Drawing D190-09-301_Issue_1.pdf
Equipment Tag Drawing D254-00-101_Issue_1.pdf
Duty Label Drawing D254-00-001_Issue_1.pdf
Pole Mount & Sun Shade Drawing D217-05-664_Issue_1__D1xC1_C2_R_.pdf

Features

  • Maximum sound pressure level output of 114dB(A)
  • Automatic synchronisation on multi-beacon & sounder systems
  • UL464 / CAN/ULC-S525 & UL1638 / CAN/ULC-S526

Specification

Alarm Horn:
Maximum output: High power level: 114dB(A) @ 1 m +/- 3dB
[105dB(A) @ 10ft/3m +/- 3dB]
Default power level: 112dB(A) @ 1 m +/- 3dB
[103dB(A) @ 10ft/3m +/- 3dB]
Class II Product version: D -17dB(A)
Nominal output: High power level: 109dB(A) @ 1m +/- 3dB
[100dB(A) @ 10ft/3m] +/- 3dB
Default power level: 107dB(A) @ 1m +/- 3dB
[98dB(A) @ 10ft/3m] +/- 3dB
Class II Product version: D -17dB(A)
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Full range
Effective range: 125m/410ft @ 1KHz
Voltages DC: 24Vdc (20-28Vdc)
Voltages AC: 110-120Vac, 220-240Vac
Stage switching: DC units: negative or positive
AC units: common supply line
Strobe Beacon:
Energy: 5 Joules (5Ws)
Flash rates: Option 1: 1Hz (60 fpm)
Option 2: 1.5Hz (90 fpm)
Option 3: Double Strike
Eff. Intensity: 143 cd* – measured ref. to I.E.S.
Peak Candela: 46,976 cd* – measured ref. to I.E.S.
Eff. Intensity: 250 cd – calculated from energy (J)
Peak Candela: 500,000 cd – calculated from energy (J)
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Tube life : Emissions reduced to 70% > 5 million flashes
General:
Safety Integrity Level: SIL1 and SIL2 Route 2H IEC61508 (2010)
Ingress protection: EN60529: IP66/67
UL50E / NEMA250: 4 / 4X / 3R / 13
Enclosure material: Marine grade aluminium LM6 – copper free
Chromated & powder coated – corrosion proof
Enclosure colour: Red or Grey, custom colours available on request
Cable entries: 1×1/2"NPT & 2xM20 – thread adaptors available
Terminals: 0.5 – 2.5mm² (20-14 AWG) Pluggable, duplicated terminals
Grounding stud: M5
Line monitoring: Blocking diode included. EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor or diode (DC versions) can be fitted
Enclosure volume: <2 litres
Installation temp: -55 to +85°C [-67° to +185°F]
Storage temp: -55 to +85°C [-67° to +185°F]
Relative humidity: 99%
Vibration test: 35Hz for a duration 4Hr (UL464)
Jarring test: 3ft/lb Energy (UL464)
Impact test: 3x 5lb (UL464)
Relative humidity: 95% – Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist
Weight: 4.9kg/10.9lbs

Current Consumption

Voltage
range:
Nominal
Voltage:
Xenon Strobe Nominal
current:
Alarm Horn Default Power
Nominal current:
Alarm Horn High Power
Nominal current:
Combined Default Power
Nominal current:
Combined High Power
Nominal current:
Combined Default Power
Maximum current:
Combined High Power
Maximum current:
In Rush
20-28Vdc 24Vdc 323mA 324mA 740mA 647mA 1063mA 647mA 1063mA 786mA <5ms
110-120Vac
50/60Hz
115Vac 130mA 125mA 285mA 255mA 415mA 291mA 478mA
220-240Vac
50/60Hz
230Vac 79mA 78mA 167mA 157mA 246mA 157mA 287mA

Part Codes

Part Code: Identifier: Description:
Product type: D1xC2X05 Combined Alarm Horn & Xenon Strobe
Horn type: R Omni-directional radial horn
Voltage: DC024
AC115
AC230
20-28V dc
110-120Vac
220-240Vac
Cable entries:[e] A
B
C
D
F
G
Note:
2 x M20x1.5mm & 1 × 1/2"NPT
2 × 1/2"NPT – adaptors
2 × 3/4"NPT – adaptors
2 x M25x1.5mm – adaptors
1 × 3/4"NPT – adaptor
1 x M25x1.5mm – adaptor
All entries, excluding thread adaptors, supplied with stopping plugs installed.
Stopping plug/
adaptor material: [m]
B
N
S
Brass
Nickel Plated
Stainless Steel
Bracket/Guard material: [s] 1
3
5

6
7
8

U bracket A4 316 Stainless Steel
U bracket A4 316 St/St with Equip. Tag
U bracket A4 316 St/St
with Equip. Tag & Duty Label
Surface bracket A4 316 SS
Surface bracket A4 316 SS with Equip. Tag
Surface bracket A4 316 SS
with Equip. Tag & Duty Label
Product version:
[v]
A
D
UL, cUL, ULC, IECEx, ATEX, CSFM – SIL1 & SIL2
Class II – UL, cUL
Product option:
[o]
1
Z
X
Y
Standard product
Custom alarm tone software – contact E2S
Custom configuration – contact E2S
Stage control Config. 4 or 8
Enclosure colour: [x] G
R
S
Grey
Red
Special colour – contact E2S
Lens colour: [y] A
B
C
G
M
R
Y
Amber
Blue
Clear
Green
Magenta
Red
Yellow
Accessories:
SP65-0001-A4
SP65-0003-A4
Pole Mount Bracket Kit St/St A4 (316)
Sunshade – St/St A4 (316)
Stage control:
Please review the installation manual and wiring schematics for remote stage control and EOL resistor monitoring configuration options:
Config. 1 or 5 [DC]: Factory default. Common negative, positive switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 2 or 6 [DC]: User setting. Common positive, negative switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 3 or 7 [DC]: User setting. Common negative, positive switching activation of Alarm Stages 1 & 2 with EOL on both stages. Reverse polarity monitoring
Config. 4 or 8 [DC]: Product option ‘Y’. Independent activation of Alarm Stages 1 & 2 with EOL on both stages. Forward polarity monitoring
Config. 1 or 2 [AC]: Factory default. Up to 4 Alarm Stages. Stage 1 activated at power on. Stages 2, 3 and 4 via volt free contacts

Approvals

  • UL/cUL/ULC File ref: E230764
  • IECEx Certificate: IECEx ULD 19.0008X
  • ATEX Certificate: DEMKO 19 ATEX 2141X
  • CSFM listing: 7136-2279:0506
  • UKCA certificate: UL21UKEX2132X

Coding

  • NEC Class / Zone
    Class I Zone 1 IIC T4 Gb Ta -55°C to +85°C
    Class I Zone 1 IIC T4A Gb Ta -55°C to +80°C
    Class I Zone 1 IIC T5 Gb Ta -55°C to +60°C
    Class I Zone 1 IIC T6 Gb Ta -55°C to +45°C
  • CEC Class / Zone
    Class I Zone 1 IIC T5 Gb Ta -55°C to +55°C
    Class I Zone 1 IIC T6 Gb Ta -55°C to +45°C
  • NEC Class / Div
    Class I Div 1 ABCD T4 Ta -55°C to +85°C
    Class I Div 1 ABCD T4A Ta -55°C to +80°C
    Class I Div 1 ABCD T5 Ta -55°C to +60°C
    Class I Div 1 ABCD T6 Ta -55°C to +45°C
  • CEC Class / Div
    Class I Div 1 ABCD T5 Ta -55°C to +55°C
    Class I Div 1 ABCD T6 Ta -55°C to +45°C
  • IECEx / ATEX
    II 2G Ex db IIC T4/T5 Gb Ta -55°C to +75°C
    II 2G Ex db IIC T5 Gb Ta -55°C to +55°C
    II 2G Ex db IIC T6 Gb Ta -55°C to +40°C (DC only)
    II 2D Ex tb IIIC T115°C Db Ta ‐55°C to +75°C
  • NEC Class / Zone – Product version: D
    Class II Zone 20 IIIB T4A Gb Ta -55°C to +70°C
  • NEC Class / Div – Product version: D
    Class II Div 1 Group FG T4A Ta -55°C to +70°C
    See product manual for full voltage specific coding.

Effective Candela lens colour factor

Amber Blue Clear Green Magenta Red Yellow
0.59 0.27 1.00 0.51 0.34 0.15 0.85

Tone Table

Stage 1 WAV file Frequency Description. Stage 2 Stage 3 Stage 4
T1 /system/1/assets/files/000/000/405/405/214ccf82a/original/TF037.WAV 1000 Continuous PFEER Toxic Gas Any T2 T44
T2 /system/1/assets/files/000/000/386/386/ceb4e488c/original/TF009.WAV 1200/500 @ 1Hz Sweeping DIN/PFEER P.T.A.P. Any T3 T44
T3 /system/1/assets/files/000/000/412/412/fa8b418f9/original/TF045.WAV 1000 @ 0.5Hz (1s on, 1s off) Intermittent PFEER Gen. Alarm Any T2 T44
T4 /system/1/assets/files/000/000/383/383/11797b764/original/TF019.WAV 1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s NF C 48-265 Any T24 T1
T5 /system/1/assets/files/000/000/382/382/2c2978b6a/original/TF017.WAV 544(100mS)/440 (400mS) NF S 32-001 Any T19 T1
T6 /system/1/assets/files/000/000/947/947/8f040484a/original/TF053.wav 1500/500 – (0.5s on , 0.5s off) x3 + 1s gap AS4428 Any T44 T1
T7 /system/1/assets/files/000/000/944/944/890010fd0/original/TF054.wav 500-1500Hz Sweeping 2 sec on 1 sec off AS4428 Any T44 T1
T8 /system/1/assets/files/000/000/417/417/abf396de0/original/TF003.WAV 500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) NEN 2575 Any T24 T35
T9 /system/1/assets/files/000/000/953/953/5deedc543/original/TF055.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) IMO Code 1a Any T34 T1
T10 /system/1/assets/files/000/000/952/952/3a041fde3/original/TF056.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) IMO Code 1a Any T34 T1
T11 /system/1/assets/files/000/000/946/946/761de34c6/original/TF057.wav 420(0.5s on, 0.5s off)x3 + 1s gap ISO 8201 Temporal Any T1 T8
T12 /system/1/assets/files/000/000/945/945/689d9405a/original/TF058.wav 1000(0.5s on, 0.5s off)x3 + 1s gap ISO 8201 Temporal Any T1 T8
T13 /system/1/assets/files/000/000/950/950/2d337d14e/original/TF059.wav 422/775 (0.85 on, 0.5 off) x3 + 1s gap NFPA Temporal Any T1 T8
T14 /system/1/assets/files/000/000/399/399/84b54dafb/original/TF034.WAV 1000/2000 @ 1Hz – Singapore Any T3 T35
T15 /system/1/assets/files/000/000/393/393/744c6f53f/original/TF030.WAV 300 Continuous Any T24 T35
T16 /system/1/assets/files/000/000/391/391/5f7a58b54/original/TF028.WAV 440 Continuous Any T24 T35
T17 /system/1/assets/files/000/000/948/948/c697b364a/original/TF060.wav 470 Continuous Any T24 T35
T18 /system/1/assets/files/000/000/949/949/7e429e658/original/TF061.wav 500 Continuous IMO code 2 (Low) Any T24 T35
T19 /system/1/assets/files/000/000/390/390/10abe0caa/original/TF027.WAV 554 Continuous Any T24 T35
T20 /system/1/assets/files/000/000/384/384/5c30f9f4d/original/TF020.WAV 660 Continuous Any T24 T35
T21 /system/1/assets/files/000/000/380/380/06feaa7b3/original/TF015.WAV 800 Continuous IMO code 2 (High) Any T24 T35
T22 /system/1/assets/files/000/000/406/406/49b88184e/original/TF043.WAV 1200 Continuous Any T24 T35
T23 /system/1/assets/files/000/000/407/407/ecce63f4f/original/TF038.WAV 2000 Continuous Any T3 T35
T24 /system/1/assets/files/000/000/421/421/b578af8a9/original/TF005.WAV 2400 Continuous Any T20 T35
T25 /system/1/assets/files/000/000/951/951/d9ce2b2c6/original/TF062.wav 440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent Any T44 T8
T26 /system/1/assets/files/000/000/954/954/b703d99f1/original/TF063.wav 470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent Any T44 T8
T27 /system/1/assets/files/000/000/955/955/0f602886a/original/TF064.wav 470 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T44 T8
T28 /system/1/assets/files/000/000/956/956/dbb5f64db/original/TF065.wav 544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent Any T24 T8
T29 /system/1/assets/files/000/000/957/957/7bd3d8c1c/original/TF066.wav 655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent Any T44 T8
T30 /system/1/assets/files/000/000/397/397/d6d84d0c3/original/TF018.WAV 660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent Any T24 T8
T31 /system/1/assets/files/000/000/381/381/93f51c79a/original/TF016.WAV 660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent Any T24 T8
T32 /system/1/assets/files/000/000/410/410/a0f0ba2a6/original/TF033.WAV 745 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T24 T8
T33 /system/1/assets/files/000/000/379/379/51c1bb5a9/original/TF014.WAV 800 (0.25s on, 1.00s off) Intermittent Any T24 T8
T34 /system/1/assets/files/000/000/388/388/b4cf9203e/original/TF023.WAV 800 @ 2Hz (0.25s on, 0.25s off) IMO code 3.a (High) Any T24 T8
T35 /system/1/assets/files/000/000/377/377/ac5498db0/original/TF011.WAV 1000 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T24 T8
T36 /system/1/assets/files/000/000/378/378/6380218ec/original/TF013.WAV 2400 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T24 T8
T37 /system/1/assets/files/000/000/958/958/a90e62da4/original/TF067.wav 2900 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T24 T8
T38 /system/1/assets/files/000/000/959/959/f34b52faa/original/TF068.wav 363/518 @ 1Hz (0.50s/0.50s) Alternating Any T8 T19
T39 /system/1/assets/files/000/000/960/960/368703340/original/TF069.wav 450/500 @ 2Hz (0.25s/0.25s) Alternating Any T8 T19
T40 /system/1/assets/files/000/000/385/385/a85a0a356/original/TF021.WAV 554/440 @ 1Hz (0.50s/0.50s) Alternating Any T24 T19
T41 /system/1/assets/files/000/000/961/961/be2680966/original/TF070.wav 554/440 @ 0.65Hz (0.76s/0.76s) Alternating Any T8 T19
T42 /system/1/assets/files/000/000/962/962/314fe8a1b/original/TF071.wav 561/760 @ 0.83Hz (0.60s/0.60s) Alternating Any T8 T19
T43 /system/1/assets/files/000/000/963/963/5f6deb8a1/original/TF072.wav 780/600 @ 0.96Hz (0.52s/0.52s) Alternating Any T8 T19
T44 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 800/1000 @ 2Hz (0.25s/0.25s) Alternating Any T24 T19
T45 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 970/800 @ 2Hz (0.25s/0.25s) Alternating Any T8 T19
T46 /system/1/assets/files/000/000/375/375/771bd7a3e/original/TF012.WAV 800/1000 @ 0.875Hz (0.57s/0.57s) Alternating Any T24 T19
T47 /system/1/assets/files/000/000/374/374/021ee6540/original/TF010.WAV 2400/2900 @ 2Hz (0.25s/0.25s) Alternating Any T24 T19
T48 /system/1/assets/files/000/000/965/965/e3d76c24c/original/TF073.wav 500/1200 @ 0.3Hz (1.67s/1.67s) Sweeping Any T24 T12
T49 /system/1/assets/files/000/000/964/964/4e1cd3f7f/original/TF074.wav 560/1055 @ 0.18Hz (2.73s/2.73s) Sweeping Any T24 T12
T50 /system/1/assets/files/000/000/966/966/a8e5f4440/original/TF075.wav 560/1055 @ 3.3Hz (0.15s/0.15s) Sweeping Any T24 T12
T51 /system/1/assets/files/000/000/969/969/5734194b1/original/TF076.wav 600/1250 @ 0.125Hz (4s/4s) Sweeping Any T24 T12
T52 /system/1/assets/files/000/000/394/394/1bfee2f1b/original/TF031.WAV 660/1200 @ 1Hz (0.50s/0.50s) Sweeping Any T24 T12
T53 /system/1/assets/files/000/000/420/420/50f9ee7a7/original/TF004.WAV 800/1000 @ 1Hz (0.50s/0.50s) Sweeping Any T24 T12
T54 /system/1/assets/files/000/000/392/392/68d5d1294/original/TF029.WAV 800/1000 @ 7Hz (0.07s/0.07s) Sweeping Any T24 T12
T55 /system/1/assets/files/000/000/389/389/68683d240/original/TF024.WAV 800/1000 @ 50Hz (0.01s/0.01s) Sweeping Any T24 T12
T56 /system/1/assets/files/000/000/422/422/42b72dd93/original/TF006.WAV 2400/2900 @ 7Hz (0.07s/0.07s) Sweeping Any T24 T12
T57 /system/1/assets/files/000/000/373/373/a686b0abe/original/TF007.WAV 2400/2900 @ 1Hz (0.50s/0.50s) Sweeping Any T24 T12
T58 /system/1/assets/files/000/000/398/398/7c1bf5e00/original/TF025.WAV 2400/2900 @ 50Hz (0.01s/0.01s) Sweeping Any T24 T12
T59 /system/1/assets/files/000/000/967/967/2e92dbc46/original/TF077.wav 2500/3000 @ 2Hz (0.25s/0.25s) Sweeping Any T24 T12
T60 /system/1/assets/files/000/000/968/968/5dfcb9aea/original/TF078.wav 2500/3000 @ 7.7Hz (0.65s/0.65s) Sweeping Any T24 T12
T61 /system/1/assets/files/000/000/408/408/e0fadcdd2/original/TF042.WAV 800Hz Motor Siren Any T24 T12
T62 /system/1/assets/files/000/000/404/404/1c1741943/original/TF041.WAV 1200Hz Motor Siren Any T24 T12
T63 /system/1/assets/files/000/000/409/409/590aa5e82/original/TF044.WAV 2400Hz Motor Siren Any T24 T12
T64 /system/1/assets/files/000/000/395/395/631e82dc8/original/TF026.WAV Simulated Bell Any T21 T12
Country specific or custom tone configurations and alarm frequencies are available upon request.

Upcoming Events

Fse (4)
Cafaa%202020%20final%20cmyk
Logo
Nfpa conference expo