STExCP8-BG: | Version: Break Glass Manual Call Point | |
Coding: | Ex db IIC T6 Gb Ta. -55°C to +70°C (Single switch) Ex db IIC T5 Gb Ta. -55°C to +70°C (Dual switch) Ex db IIC T6 Gb Ta. -55°C to +60°C (Dual switch) |
|
Switch: | Sealed – IP67 | |
Ingress protection: | EN/IEC 60529 – IP66/67 | |
Enclosure matl: | 316L Stainless Steel | |
Colour: | RAL3000 Red (others available on request) | |
Cable entries: | 2 x M20x1.5 top and 1 x M20x1.5 side. Back box can be rotated to give 2 x bottom and 1 x side entries |
|
Stopping plugs: | 2 × 316 Stainless Steel plugs as standard Brass and Nickel plated plugs optional |
|
Terminals: | DIN rail 8 × 2.5mm² SAK2.5 or Termination board featuring 6 × 2.5mm² terminals plus 4 x dedicated EOL & Series terminals |
|
Earth: | External M5 earth connection | |
Relative Humidity: | R.H. 95% @ 20°C | |
Test: | Test key facility | |
MTBF: | 479.6 years / 4,201,680 hours - MIL 217 | |
Weight: | 4.2Kg/9.26Ibs | |
Voltage Range: |
Max input Current: |
Limitations for EOL / Series Resistors: |
250Vac Max | 5.0A max | not permitted |
48Vdc Max | 1.0A max | min. 2.2kOhm |
24Vdc Max | 3.0A max | min. 470 Ohm |
EOL and Series Diode Values: | ||
xxx: | Zener Value | Max. current supply permitted |
3V3 | 3.3V Diode | 230mA |
4V7 | 4.7V Diode | 162mA |
5V1 | 5.1V Diode | 149mA |
5V6 | 5.6V Diode | 136mA |
6V2 | 6.2V Diode | 122mA |
6V8 | 6.8V Diode | 112mA |
10V | 10V Diode | 76mA |
12V | 12V Diode | 63mA |
Version: | Part reference: | Description: |
---|---|---|
Product type: | STExCP8BG | Break Glass Manual Call Point |
Switch type: [s] | S D |
SPCO/SPDT DPCO/DPDT |
Terminals: [t] | D P |
DIN Rail 8 × SAK2.5 Termination board: 6 × 2.5mm² terminals plus 4 × EOL & Series terminals |
Lift flap: [l] | L N |
Lift flap No lift flap |
Cable entries:[e] | A B C D E F G |
3 x M20x1.5mm 2 × 1/2" NPT – adaptors 2 × 3/4" NPT – adaptors 2 x M25x1.5mm – adaptors 1 × 1/2" NPT – adaptor 1 × 3/4" NPT – adaptor 1 x M25x1.5mm – adaptor |
Stopping plug/ adaptor material: [m] |
S | Stainless Steel |
Duty label/Equipment tag: [d]: | 1 2 3 4 5 6 7 |
No Duty label, no Equip. tag Duty label Stainless Steel Duty label St/St + Equip. tag Duty label Metalised Polyester Duty label M. Poly. + Equip. tag Equip. tag only Special label requirement |
Product version: [v] |
A H Z M C P |
IECEx, ATEX, Ex EAC, PESO & DNV approved Honeywell TC809B1008 module IECEx, ATEX Ziton A45E-2 module IECEx, ATEX Johnson Controls MIM800 module IECEx, ATEX Hochiki CHQ-CP2 monitor IECEx, ATEX Apollo XP95 mini module IECEx, ATEX |
Product option: [o] | 1 | Standard product |
Enclosure colour: [x] | R B N Y V S K M Z |
Red Blue Green Yellow Red/White Yellow/Black Black Magenta Red/Black |
Default: [u] | N | Default = N – not currently used |
E.O.L.Module: [e] optional |
ExxxR ED1 ExxxZ |
Resistor value in Ohms e.g. E470R = 470 Ohm Diode IN4007 = ED1 Zener diode e.g. E5V1Z = 5.1V |
Series Module: [s] optional |
SxxxR SD1 SxxxZ |
Resistor value in Ohms e.g. S1K5R = 1.5K Ohm Diode IN4007 = SD1 Zener diode e.g. S5V1Z = 5.1V |
Spares: | ||
SP70-0001 SP70-0040 |
Replacement break glass elements (Pack of 50) STxCP8-BG Test Key |
|
Accessories: | ||
SP65-0001-A4 SP65-0002-A4 SP70-0065 |
Pole Mount Bracket Kit 2" St/St A4 (316) Sunshade – St/St A4 (316) Break glass hammer with chain |
|