D1xC1F Horn/Speaker Strobe 1-23-045

Product image
Product Image
The D1xCF is a unique solution for combined audible and visual public notification in explosion proof environments. With a choice of either alarm horn or speaker the D1xCF features a factory assembled configuration integrating the audible signal with a high output Xenon strobe with 86cd or 190cd options.
Request a quote for this product
Strobe type
Horn or Speaker type
Cable entries
Stopping plug/Adaptor material
Tag/Duty label
Product version
Product option
Assembly color
Part Number:
D1xC1F
Request Price or enquire about this product
Enquire about
Horn/Speaker Strobe

New Product

  • Unique solution for public mode Class I Division 1 notification
  • Factory assembled combined signal
  • Reduces cabling and installation costs
  • Available with either horn or speaker
  • Choice of Xenon strobe outputs
  • 316L stainless steel back plate
  • Includes pole/pipe mount kit

Description

Robust Type 4/4X, IP66 marine grade, corrosion proof aluminium enclosures with 316L stainless steel back plate – approved for Class I Division 1 and Class I Zone 1 applications. Horn options offer 115dB(A) or 123dB(A) sound level outputs employing class D amplification to provide a high sound output at optimum operating current. Multiple horn & strobe D1xCF units will auto-synchronize when powered from the same source, removing the need for sync modules.

Downloads

Datasheet Datasheet.pdf
D1xCF Speaker & Strobe Install manual D226-01-425-IS_Issue_1_D1xCF_L.pdf
D1xCF Horn & Strobe Install manual D226-01-325-IS_Issue_1_D1xCF_S.pdf
2D drawing (PDF) D226-05-325_Issue_2.pdf
2D drawing (DWG) D226-05-325_Issue_2.DWG
3D drawing (STEP) D226-05-325-3D_Issue_1_S1F_L1F.STEP
3D drawing (STEP) D226-05-325-3D_Issue_1_S2F_L2F.STEP
Wiring Schematic Speaker & Strobe D226-06-325_Issue_1_Speaker_Strobe.pdf
Wiring Schematic Horn & Strobe D226-06-425_Issue_1_Horn_Strobe.pdf

Features

  • UL464 and CAN/ULC-S525
  • UL1480 and CAN/ULC-S541
  • UL1971 & UL1638 and CAN/ULC-S526
  • Public & private mode fire use
  • Choice of three flash rates: 1Hz, 1.3Hz & 1.5Hz
  • Automatic synchronization on multi-horn & strobe systems
  • Alarm horn: integrated tone generator with 64 alarm tones
  • Speaker: 15W or 25W models with 25/70V transformer
  • Marine grade aluminium enclosure
  • Ingress protection Type 4/4X/3R/13, IP66
  • High impact resistant Borosilicate glass lens
  • Supervisory diode – duplicated terminals
  • Dual 1/2"NPT entries with haz loc rated stopping plugs
  • 316L stainless steel back plate
  • Supplied with stainless steel pole mount kit

Specification

Horn option Model: D1xS1F – part code ref: S1F
Maximum output: 115dB(A) @ 1m [106dB(A) @ 10ft/3m] +/- 3dB
Nominal output: 110dB(A) @ 1m [101dB(A) @ 10ft/3m] +/- 3dB – Tone 4
Synchronization: Automatic synchronization
Volume control: Full range
Horn option Model: D1xS2F – part code ref: S2F
Maximum output: High power: 123dB(A) @ 1m [114dB(A) @ 10ft/3m] +/- 3dB
Default power: 120dB(A) @ 1m [111dB(A) @ 10ft/3m] +/- 3dB
Nominal output: High power: 118dB(A) @ 1m [109dB(A) @ 10ft/3m] +/- 3dB
Default power: 115dB(A) @ 1m [106dB(A) @ 10ft/3m] +/- 3dB
Synchronization: Automatic synchronization
Volume control: Full range
Speaker option Model: D1xL1F – part code ref: L1F
Sound output: 101dB @ 1W @ 1m [92dB(A) @ 10ft/3m] (Pink) +/- 3dB
113dB @ 15W @ 1m [104dB(A) @ 10ft/3m] (Rated) +/- 3dB
120dB(A) @ 1m at 1.3Khz [111dB(A) @ 10ft/3m] (Max)
25/70v line tappings: 15W/7.5W/5W/4W/2W
25V: z=41.67/83.34/125/156.25/312.5K Ohm
70V: z=326.67/653.34/980/1.225K/2.45K Ohm
Speaker option Model: D1xL2F – part code ref: L2F
Sound output: 104dB @ 1W @ 1m [95dB(A) @ 10ft/3m] (Pink) +/- 3dB
119dB @ 25W @ 1m [110dB(A) @ 10ft/3m] (Rated) +/- 3dB
124dB(A) @ 1m at 1.3Khz [115dB(A) @ 10ft/3m] (Max)
25/70v line tappings: 25W/12.5W/6W/2W/1W tappings
25V: z=196/392/816.67/1.225K/2.45K/4.9K Ohm
70V: z=25/50/104.17/156.25K/312.5K/625 Ohm
Xenon option Model: D1xB2XH1 – part code ref: 6C
Source: Xenon strobe 10 Joules (10Ws)
Modes: 1Hz flash (60 fpm)
1.3Hz flash (80 fpm)
1.5Hz flash (90 fpm)
Double flash (120 fpm)
Effective cd: 86.37cd – UL1971
Xenon option Model: D1xB2XH2 – part code ref: 7C
Source: Xenon strobe 21 Joules (21Ws)
Modes: 1Hz flash (60 fpm)
1.3Hz flash (80 fpm)
1.5Hz flash (90 fpm)
Double flash (120 fpm)
Effective cd: 190.00cd – UL1971
General data
Ingress protection: EN60529:IP66, UL50E/NEMA250:4/4X/3R/13
Enclosure material: Marine grade LM6 aluminum alloy – Chromate & powder coated finish
Lens material: Toughened borosilicate glass
Cable entries: 1 × 3/4"NPT – Nickel Plated Brass plugs included
Terminals: 0.5 – 2.5mm² (20-14AWG) – 12AWG solid core conductor
Pluggable & duplicated terminals
Line monitoring: Supervisory/Blocking diode included
EOL Min. 1K Ohm 2W, or 3K9 Ohm 0.5W resistor
Operating temp: -55 to +80°C [-67° to +176°F]
Storage temp: -55 to +80°C [-67° to +176°F]
Relative humidity: 99% – tropicalised/conformal coated electronics
Weight: 10.0Kg/22.04lbs

Current Consumption

Component
product:
Part code
ref.:
Nominal
voltage:
Nominal
current:
Max.
current:
Max.
in-rush:
Xenon Strobe D1xB2XH1 6C 24Vdc 635mA 765mA 817mA <5ms
Xenon Strobe D1xB2XH2 7C 24Vdc 1165mA 1360mA 1500mA <5ms
Alarm Horn D1xS1F S1F 24Vdc 185mA 221mA 815mA <4ms
Alarm Horn D1xS2F S2F 24Vdc Default: 324mA
High power: 740mA
Default: 324mA
High power: 740mA
815mA <4ms

Part Codes

Part Code: Identifier: Description:
Product type: D1xCF Combined Horn/Speaker Strobe
Strobe type: 6C
7C
D1xB2XH1 86.37cd Xenon strobe
D1xB2XH2 190.00cd Xenon strobe
Horn or Speaker type: S1F
S2F
L1F
L2F
D1xS1F Alarm horn 106dB(A) @ 10ft
D1xS2F Alarm horn 111/114dB(A) @ 10ft
D1xL1F 15W Speaker 25/70V line
D1xL2F 25W Speaker 25/70V line
Cable entries: M
B
C
F
1×3/4"NPT + 1xM20x1.5mm – Default
2×1/2"NPT – adaptors
1×3/4"NPT + 1×3/4"NPT – adaptor
1×3/4"NPT + 1×1/2"NPT – adaptor
Stopping plug/Adaptor material: N Nickel plated brass
Tag/Duty label: 1
3
316 Stainless steel equipment tag
316 Stainless steel equip. tag & duty label
Product version: C UL/cUL/ULC Class I Division 1, Class I Zone 1
Product option: 1
W
Standard wiring
Special wiring
Assembly color: R Red

Part code examples:
D1xCF7CS2FMN1C1R
D1xCF: Horn/Speaker Strobe
7C: 190.00cd Xenon strobe
S2F: 111/114dB(A) alarm horn
M: 1×3/4"NPT + 1xM20x1.5mm cable entries
N: Nickel plated brass stopping plugs
1: Stainless steel equipment tag (specify required contents)
C: UL/cUL/ULC approval for Class I Div 1 and Zone 1
1: Standard product wiring
R: Red enclosure and stainless steel back plate
D1xCF6CL1FBN3C1R
D1xCF: Horn/Speaker Strobe
6C: 86.37cd Xenon strobe
L1F: 15W 25/70V Speaker
B: 2×1/2"NPT cable entries
N: Nickel plated brass stopping plugs
3: Stainless steel equipment tag & duty label (specify required contents)
C: UL/cUL/ULC approval for Class I Div 1 and Zone 1
1: Standard product wiring
R: Red enclosure and stainless steel back plate

Approvals

  • Component listings:
    UL/cUL/ULC File ref: E230764
    CSFM listing: 7136-2279:0506

Coding

  • NEC Class Div
    Class I Div 1 Group ABCD T4A Ta -67° to +176°F
    Class I Div 1 Group ABCD T5 Ta -67°C to +131°C
    Class I Div 1 Group ABCD T6 Ta -67°C to +104°C
  • NEC Class Zone
    Class I Zone 1 AEx db IIC T4 Ta -67° to +176°F
    Class I Zone 1 AEx db IIC T5 Ta -67°C to +131°C
    Class I Zone 1 AEx db IIC T6 Ta -67°C to +104°C
  • CEC Class Zone
    Ex db IIC T4 Ta -67°C to +167°C
    Ex db IIC T5 Ta -67°C to +131°C
    Ex db IIC T6 Ta -67°C to +104°C
    Above represents minimum assembly coding.
    See component product manuals for full coding.

Tone Table

Stage 1 WAV file Frequency Description. Stage 2 Stage 3 Stage 4
T1 /system/1/assets/files/000/000/405/405/214ccf82a/original/TF037.WAV 1000 Continuous PFEER Toxic Gas Any T2 T44
T2 /system/1/assets/files/000/000/386/386/ceb4e488c/original/TF009.WAV 1200/500 @ 1Hz Sweeping DIN/PFEER P.T.A.P. Any T3 T44
T3 /system/1/assets/files/000/000/412/412/fa8b418f9/original/TF045.WAV 1000 @ 0.5Hz (1s on, 1s off) Intermittent PFEER Gen. Alarm Any T2 T44
T4 /system/1/assets/files/000/000/383/383/11797b764/original/TF019.WAV 1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s NF C 48-265 Any T24 T1
T5 /system/1/assets/files/000/000/382/382/2c2978b6a/original/TF017.WAV 544(100mS)/440 (400mS) NF S 32-001 Any T19 T1
T 6 /system/1/assets/files/000/000/947/947/8f040484a/original/TF053.wav 1500/500 – (0.5s on , 0.5s off) x3 + 1.5s gap – AS4428 Any T 44 T 1
T 7 /system/1/assets/files/000/000/944/944/890010fd0/original/TF054.wav 500-1500Hz Sweeping 2 sec on 1 sec off – AS4428 Any T 44 T 1
T 8 /system/1/assets/files/000/000/417/417/abf396de0/original/TF003.WAV 500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) – NEN 2575 Any T 24 T 35
T 9 /system/1/assets/files/000/000/953/953/5deedc543/original/TF055.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 10 /system/1/assets/files/000/000/952/952/3a041fde3/original/TF056.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 11 /system/1/assets/files/000/000/946/946/761de34c6/original/TF057.wav 420(0.5s on, 0.5s off)x3 + 1.5s gap – ISO 8201 Temporal Any T 1 T 8
T 12 /system/1/assets/files/000/000/945/945/689d9405a/original/TF058.wav 1000(0.5s on, 0.5s off)x3 + 1.5s gap – ISO 8201 Temporal Any T 1 T 8
T 13 /system/1/assets/files/000/000/950/950/2d337d14e/original/TF059.wav 422/775 – (0.85 on, 0.5 off) x3 + 1.5s gap – NFPA Temporal Any T 1 T 8
T14 /system/1/assets/files/000/000/399/399/84b54dafb/original/TF034.WAV 1000/2000 @ 1Hz – Singapore Any T3 T35
T15 /system/1/assets/files/000/000/393/393/744c6f53f/original/TF030.WAV 300 Continuous Any T24 T35
T16 /system/1/assets/files/000/000/391/391/5f7a58b54/original/TF028.WAV 440 Continuous Any T24 T35
T17 /system/1/assets/files/000/000/948/948/c697b364a/original/TF060.wav 470 Continuous Any T24 T35
T18 /system/1/assets/files/000/000/949/949/7e429e658/original/TF061.wav 500 Continuous IMO code 2 (Low) Any T24 T35
T19 /system/1/assets/files/000/000/390/390/10abe0caa/original/TF027.WAV 554 Continuous Any T24 T35
T20 /system/1/assets/files/000/000/384/384/5c30f9f4d/original/TF020.WAV 660 Continuous Any T24 T35
T21 /system/1/assets/files/000/000/380/380/06feaa7b3/original/TF015.WAV 800 Continuous IMO code 2 (High) Any T24 T35
T22 /system/1/assets/files/000/000/406/406/49b88184e/original/TF043.WAV 1200 Continuous Any T24 T35
T23 /system/1/assets/files/000/000/407/407/ecce63f4f/original/TF038.WAV 2000 Continuous Any T3 T35
T24 /system/1/assets/files/000/000/421/421/b578af8a9/original/TF005.WAV 2400 Continuous Any T20 T35
T25 /system/1/assets/files/000/000/951/951/d9ce2b2c6/original/TF062.wav 440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent Any T44 T8
T26 /system/1/assets/files/000/000/954/954/b703d99f1/original/TF063.wav 470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent Any T44 T8
T27 /system/1/assets/files/000/000/955/955/0f602886a/original/TF064.wav 470 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T44 T8
T28 /system/1/assets/files/000/000/956/956/dbb5f64db/original/TF065.wav 544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent Any T24 T8
T29 /system/1/assets/files/000/000/957/957/7bd3d8c1c/original/TF066.wav 655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent Any T44 T8
T30 /system/1/assets/files/000/000/397/397/d6d84d0c3/original/TF018.WAV 660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent Any T24 T8
T31 /system/1/assets/files/000/000/381/381/93f51c79a/original/TF016.WAV 660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent Any T24 T8
T32 /system/1/assets/files/000/000/410/410/a0f0ba2a6/original/TF033.WAV 745 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T24 T8
T33 /system/1/assets/files/000/000/379/379/51c1bb5a9/original/TF014.WAV 800 (0.25s on, 1.00s off) Intermittent Any T24 T8
T34 /system/1/assets/files/000/000/388/388/b4cf9203e/original/TF023.WAV 800 @ 2Hz (0.25s on, 0.25s off) IMO code 3.a (High) Any T24 T8
T35 /system/1/assets/files/000/000/377/377/ac5498db0/original/TF011.WAV 1000 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T24 T8
T36 /system/1/assets/files/000/000/378/378/6380218ec/original/TF013.WAV 2400 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T24 T8
T37 /system/1/assets/files/000/000/958/958/a90e62da4/original/TF067.wav 2900 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T24 T8
T38 /system/1/assets/files/000/000/959/959/f34b52faa/original/TF068.wav 363/518 @ 1Hz (0.50s/0.50s) Alternating Any T8 T19
T39 /system/1/assets/files/000/000/960/960/368703340/original/TF069.wav 450/500 @ 2Hz (0.25s/0.25s) Alternating Any T8 T19
T40 /system/1/assets/files/000/000/385/385/a85a0a356/original/TF021.WAV 554/440 @ 1Hz (0.50s/0.50s) Alternating Any T24 T19
T41 /system/1/assets/files/000/000/961/961/be2680966/original/TF070.wav 554/440 @ 0.65Hz (0.76s/0.76s) Alternating Any T8 T19
T42 /system/1/assets/files/000/000/962/962/314fe8a1b/original/TF071.wav 561/760 @ 0.83Hz (0.60s/0.60s) Alternating Any T8 T19
T43 /system/1/assets/files/000/000/963/963/5f6deb8a1/original/TF072.wav 780/600 @ 0.96Hz (0.52s/0.52s) Alternating Any T8 T19
T44 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 800/1000 @ 2Hz (0.25s/0.25s) Alternating Any T24 T19
T45 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 970/800 @ 2Hz (0.25s/0.25s) Alternating Any T8 T19
T46 /system/1/assets/files/000/000/375/375/771bd7a3e/original/TF012.WAV 800/1000 @ 0.875Hz (0.57s/0.57s) Alternating Any T24 T19
T47 /system/1/assets/files/000/000/374/374/021ee6540/original/TF010.WAV 2400/2900 @ 2Hz (0.25s/0.25s) Alternating Any T24 T19
T48 /system/1/assets/files/000/000/965/965/e3d76c24c/original/TF073.wav 500/1200 @ 0.3Hz (1.67s/1.67s) Sweeping Any T24 T12
T49 /system/1/assets/files/000/000/964/964/4e1cd3f7f/original/TF074.wav 560/1055 @ 0.18Hz (2.73s/2.73s) Sweeping Any T24 T12
T50 /system/1/assets/files/000/000/966/966/a8e5f4440/original/TF075.wav 560/1055 @ 3.3Hz (0.15s/0.15s) Sweeping Any T24 T12
T51 /system/1/assets/files/000/000/969/969/5734194b1/original/TF076.wav 600/1250 @ 0.125Hz (4s/4s) Sweeping Any T24 T12
T52 /system/1/assets/files/000/000/394/394/1bfee2f1b/original/TF031.WAV 660/1200 @ 1Hz (0.50s/0.50s) Sweeping Any T24 T12
T53 /system/1/assets/files/000/000/420/420/50f9ee7a7/original/TF004.WAV 800/1000 @ 1Hz (0.50s/0.50s) Sweeping Any T24 T12
T54 /system/1/assets/files/000/000/392/392/68d5d1294/original/TF029.WAV 800/1000 @ 7Hz (0.07s/0.07s) Sweeping Any T24 T12
T55 /system/1/assets/files/000/000/389/389/68683d240/original/TF024.WAV 800/1000 @ 50Hz (0.01s/0.01s) Sweeping Any T24 T12
T56 /system/1/assets/files/000/000/422/422/42b72dd93/original/TF006.WAV 2400/2900 @ 7Hz (0.07s/0.07s) Sweeping Any T24 T12
T57 /system/1/assets/files/000/000/373/373/a686b0abe/original/TF007.WAV 2400/2900 @ 1Hz (0.50s/0.50s) Sweeping Any T24 T12
T58 /system/1/assets/files/000/000/398/398/7c1bf5e00/original/TF025.WAV 2400/2900 @ 50Hz (0.01s/0.01s) Sweeping Any T24 T12
T59 /system/1/assets/files/000/000/967/967/2e92dbc46/original/TF077.wav 2500/3000 @ 2Hz (0.25s/0.25s) Sweeping Any T24 T12
T60 /system/1/assets/files/000/000/968/968/5dfcb9aea/original/TF078.wav 2500/3000 @ 7.7Hz (0.65s/0.65s) Sweeping Any T24 T12
T61 /system/1/assets/files/000/000/408/408/e0fadcdd2/original/TF042.WAV 800Hz Motor Siren Any T24 T12
T62 /system/1/assets/files/000/000/404/404/1c1741943/original/TF041.WAV 1200Hz Motor Siren Any T24 T12
T63 /system/1/assets/files/000/000/409/409/590aa5e82/original/TF044.WAV 2400Hz Motor Siren Any T24 T12
T64 /system/1/assets/files/000/000/395/395/631e82dc8/original/TF026.WAV Simulated Bell Any T21 T12
Country specific or custom tone configurations and alarm frequencies are available upon request.

Upcoming Events

Intersec logo %28png%29
Adipec 2025 logo   0224
Fse (4)
Nfpa conference expo