D2xCF Horn/Speaker Strobe 1-34-090

Product image
Product Image
The D2xCF is the optimum solution for public mode fire alarm signalling in hazardous locations. With a choice of either alarm horn or speaker the factory assembled configuration integrates the audible signal with a high output 79.3cd output LED strobe or 70.29cd Xenon.
Request a quote for this product
Strobe type
Horn or Speaker type
Cable entries
Stopping plug/Adaptor material
Tag/Duty label
Product version
Product option
Assembly color
Part Number:
D2xCF
Request Price or enquire about this product
Enquire about
Horn/Speaker Strobe

New Product

  • Unique solution for public mode Class I/II Division 2 notification
  • Factory assembled combined signal
  • Reduces cabling and installation costs
  • Available with either horn or speaker
  • High output LED strobe
  • 316L stainless steel back plate
  • Includes pole/pipe mount kit

Description

Robust Type 4/4X, IP66 marine grade, corrosion proof aluminium enclosures with 316L stainless steel back plate – approved for Class I/II Division 2 and Class I Zone 2/22 applications. The D2xCF combines the industry leading D2xB1LD3 LED or D2xB1XH2 Xenon strobe with a 123dB(A) horn or 15W or 25W speaker. The strobe utilises an array of super high power Cree® LED’s, orientated to optimise visibility. The alarm horn employs class D amplification to provide a high sound output at optimum operating current.

Downloads

Datasheet Datasheet.pdf
D2xCF Speaker & Strobe Install manual D215-01-425-IS_Issue_1_D2xCF_L.pdf
D2xCF Horn & Strobe Install manual D215-01-325-IS_Issue_1_D2xCF_S.pdf
2D drawing (PDF) D215-05-325_Issue_2.pdf
2D drawing (DWG) D215-05-325_Issue_2.DWG
3D drawing (STEP) D215-05-325-3D_Issue_1_S1F_L1F.STEP
3D drawing (STEP) D215-05-325-3D_Issue_1_S2F_L2F.STEP
Wiring Schematic Speaker & Strobe D215-06-325_Issue_1_Speaker_Strobe.pdf
Wiring Schematic Horn & Strobe D215-06-425_Issue_1_Horn_Strobe.pdf

Features

  • UL464 and CAN/ULC-S525
  • UL1480 and CAN/ULC-S541
  • UL1971 & UL1638 and CAN/ULC-S526
  • Public & private mode fire use
  • Automatic synchronization on multi-horn & strobe systems
  • Alarm horn: integrated tone generator with 64 alarm tones
  • Speaker: 15W or 25W models with 25/70V transformer
  • Marine grade aluminium enclosure
  • Ingress protection Type 4/4X/3R/13, IP66
  • High impact resistant Borosilicate glass lens
  • Supervisory diode – duplicated terminals
  • Dual 1/2"NPT entries with haz loc rated stopping plugs
  • 316L stainless steel back plate
  • Supplied with stainless steel pole mount kit

Specification

Horn option Model: D2xS2F – part code ref: S2F
Maximum output: High power: 123dB(A) @ 1 m [114dB(A) @ 10ft/3m] +/- 3dB
Default power: 120dB(A) @ 1 m [111dB(A) @ 10ft/3m] +/- 3dB
Nominal output: High power: 120dB(A) @ 1m [111dB(A) @ 10ft/3m] +/- 3dB
Default power: 117dB(A) @ 1m [108dB(A) @ 10ft/3m] +/- 3dB
Synchronization: Automatic synchronization
Volume control: Full range
Speaker option Model: D2xL1F – part coe ref: L1F
Sound output: 101dB @ 1W @ 1m [92dB(A) @ 10ft/3m] (Pink) +/- 3dB
113dB @ 15W @ 1m [104dB(A) @ 10ft/3m] (Rated) +/- 3dB
120dB(A) @ 1m at 1.3Khz [111dB(A) @ 10ft/3m] (Max)
25/70v line tappings: 15W/7.5W/5W/4W/2W
25V: z=41.67/83.34/125/156.25/312.5K Ohm
70V: z=326.67/653.34/980/1.225K/2.45K Ohm
Speaker option Model: D2xL2F – part code ref: L2F
Sound output: 104dB @ 1W @ 1m [95dB(A) @ 10ft/3m] (Pink) +/- 3dB
119dB @ 25W @ 1m [110dB(A) @ 10ft/3m] (Rated) +/- 3dB
124dB(A) @ 1m at 1.3Khz [115dB(A) @ 10ft/3m] (Max)
25/70v line tappings: 25W/12.5W/6W/2W/1W tappings
25V: z=196/392/816.67/1.225K/2.45K/4.9K Ohm
70V: z=25/50/104.17/156.25K/312.5K/625 Ohm
Xenon option Model: D2xB1XH2 – part code ref: 7C
Source: Xenon strobe 10 Joules (10Ws)
Modes: 1Hz flash (60 fpm)
Effective cd: 70.29 cd – UL1971
Effective cd: 500 cd – calculated from energy (J)
LED option Model: D2xB1LD3 – part code ref: 8C
Source: Array of 3 x High Power Cree® LED’s
Pulse width: 20ms – high intensity ‘strobe’ flash
Modes: 1Hz flash (60 fpm), 1.3Hz flash (80 fpm)
1.5Hz flash (90 fpm), 2Hz flash (120 fpm
Eff. Intensity cd: 79.3 cd UL1971 Public mode fire
Eff. Intensity cd: 107.5 cd UL1638 Private mode fire
Eff. Intensity cd: 252.0 cd UL1638 General signaling
LED life: >60,000 hours
General data
Ingress protection: EN60529:IP66, UL50E/NEMA250:4/4X/3R/13
Enclosure material: Marine grade LM6 aluminum alloy – Chromate & powder coated finish
Lens material: Toughened borosilicate glass
Cable entries: 2 × 1/2"NPT – Nickel Plated Brass plugs included
Terminals: 0.5 – 2.5mm² (20-14AWG) – 12AWG solid core conductor
Pluggable & duplicated terminals
Line monitoring: Supervisory/Blocking diode included
EOL Min. 1K Ohm 2W, or 3K9 Ohm 0.5W resistor
Operating temp: -40 to +50°C [-40° to +122°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 99% – tropicalised/conformal coated electronics
Weight: 8.0Kg/17.63lbs

Current Consumption

Component
product:
Part code
ref.:
Nominal
voltage:
Nominal
current:
Max.
current:
Max.
in-rush:
Xenon Strobe D2xB1XH2 7C 24Vdc 609mA 609mA 828mA <4.4ms
LED Strobe D2xB1LD3 8C 24Vdc 189mA 488mA 1180mA <7.0ms
Alarm Horn D2xS2F S2F 24Vdc Default: 324mA
High power: 740mA
Default: 324mA
High power: 740mA
815mA <4ms

Part Codes

Part Code: Identifier: Description:
Product type: D2xCF Combined Speaker Strobe
Strobe type: 7C
8C
D2xB1XH2 70.29cd Xenon strobe
D2xB1LD3 79.30cd LED strobe
Horn or Speaker type: S2F
L1F
L2F
D2xS2F Alarm horn 111/114dB(A) @ 10ft
D2xL1F 15W Speaker 25/70V line
D2xL2F 25W Speaker 25/70V line
Cable entries: M 1×3/4"NPT + 2×1/2"NPT + 2xM20x1.5mm
Stopping plug/Adaptor material: N Nickel plated brass
Tag/Duty label: 1
3
316 Stainless steel equipment tag
316 Stainless steel equip. tag & duty label
Product version: A UL/cUL/ULC Class I/II Division 2, Class I Zone 2/22, ATEX & IECEx
Product option: 1
W
Standard wiring
Special wiring
Assembly color: R Red

Part code examples:
D2xCF8CS2FMN1A1R
D2xCF: Horn/Speaker Strobe
8C: 79.30cd LED strobe
S2F: 111/114dB(A) alarm horn
M: 1×3/4"NPT + 2×1/2"NPT + 2xM20x1.5mm cable entries
N: Nickel plated brass stopping plugs
1: Stainless steel equipment tag (specify required contents)
A: UL/cUL/ULC/ATEX/IECEx approval for Class I/II Division 2, Class I Zone 2/22
1: Standard product wiring
R: Red enclosure and stainless steel back plate
D2xCF7CL2FMN3A1R
D2xCF: Horn/Speaker Strobe
7C: 86.37cd Xenon strobe
L1F: 15W 25/70V Speaker
M: 1×3/4"NPT + 2×1/2"NPT + 2xM20x1.5mm cable entries
N: Nickel plated brass stopping plugs
3: Stainless steel equipment tag & duty label (specify required contents)
A: UL/cUL/ULC/ATEX/IECEx approval for Class I/II Division 2, Class I Zone 2/22
1: Standard product wiring
R: Red enclosure and stainless steel back plate

Approvals

  • Component listings:
    UL File ref: E230764
    CSFM listing: 7136-2279:0501
    IECEx cert: IECEx ULD 14.0004X
    ATEX cert: DEMKO 14 ATEX 4786493904X

Coding

  • NEC/CEC Class Div
    Class I Div 2 ABCD T1 Ta -40° to +122°F
    Class II Div 2 FG T4 Ta -40° to +122°F
    Class III Div 1&2 Ta -40° to +122°F
  • NEC Class Zone
    Class I Zone 2 AEx ec IIC Gc T1 Ta -40° to +122°F
    Zone 22 AEx tc IIIB T75°C Dc Ta -40° to +122°F
  • CEC Class Zone
    Class I Zone 2 Ex ec IIC Gc X T1 Ta -40° to +122°F
    Zone 22 Ex tc IIIC T75°C Dc X Ta -40° to +122°F
  • IECEx & ATEX
    II 3G Ex ec IIC T1 Gc Ta -40° to +122°F
    II 3D Ex tc IIIC T75°C Dc Ta -40° to +122°F
    Above represents minimum assembly coding.
    See component product manuals for full coding.

Tone Table

Stage 1 WAV file Frequency Description. Stage 2 Stage 3 Stage 4
T 1 /system/1/assets/files/000/000/405/405/214ccf82a/original/TF037.WAV 1000 Continuous – PFEER Toxic Gas T 3 T 2 T 44
T 2 /system/1/assets/files/000/000/386/386/ceb4e488c/original/TF009.WAV 1200/500 @ 1Hz Sweeping – DIN / PFEER P.T.A.P. T 1 T 3 T 44
T 3 /system/1/assets/files/000/000/412/412/fa8b418f9/original/TF045.WAV 1000 @ 0.5Hz (1s on, 1s off) Intermittent – PFEER Gen. Alarm T 1 T 2 T 44
T 4 /system/1/assets/files/000/000/383/383/11797b764/original/TF019.WAV 1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s – NF C 48-265 T 44 T 24 T 1
T 5 /system/1/assets/files/000/000/382/382/2c2978b6a/original/TF017.WAV 544(100mS)/440 (400mS) – NF S 32-001 T 52 T 19 T 1
T 6 /system/1/assets/files/000/000/947/947/8f040484a/original/TF053.wav 1500/500 – (0.5s on , 0.5s off) x3 + 1.5s gap – AS4428 Any T 44 T 1
T 7 /system/1/assets/files/000/000/944/944/890010fd0/original/TF054.wav 500-1500Hz Sweeping 2 sec on 1 sec off – AS4428 Any T 44 T 1
T 8 /system/1/assets/files/000/000/417/417/abf396de0/original/TF003.WAV 500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) – NEN 2575 Any T 24 T 35
T 9 /system/1/assets/files/000/000/953/953/5deedc543/original/TF055.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 10 /system/1/assets/files/000/000/952/952/3a041fde3/original/TF056.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 11 /system/1/assets/files/000/000/946/946/761de34c6/original/TF057.wav 420(0.5s on, 0.5s off)x3 + 1.5s gap – ISO 8201 Temporal Any T 1 T 8
T 12 /system/1/assets/files/000/000/945/945/689d9405a/original/TF058.wav 1000(0.5s on, 0.5s off)x3 + 1.5s gap – ISO 8201 Temporal Any T 1 T 8
T 13 /system/1/assets/files/000/000/950/950/2d337d14e/original/TF059.wav 422/775 – (0.85 on, 0.5 off) x3 + 1.5s gap – NFPA Temporal Any T 1 T 8
T 14 /system/1/assets/files/000/000/399/399/84b54dafb/original/TF034.WAV 1000/2000 @ 1Hz – Singapore T 23 T 3 T 35
T 15 /system/1/assets/files/000/000/393/393/744c6f53f/original/TF030.WAV 300 Continuous T 44 T 24 T 35
T 16 /system/1/assets/files/000/000/391/391/5f7a58b54/original/TF028.WAV 440 Continuous T 44 T 24 T 35
T 17 /system/1/assets/files/000/000/948/948/c697b364a/original/TF060.wav 470 Continuous T 44 T 24 T 35
T 18 /system/1/assets/files/000/000/949/949/7e429e658/original/TF061.wav 500 Continuous – IMO code 2 (Low) T 44 T 24 T 35
T 19 /system/1/assets/files/000/000/390/390/10abe0caa/original/TF027.WAV 554 Continuous T 64 T 24 T 35
T 20 /system/1/assets/files/000/000/384/384/5c30f9f4d/original/TF020.WAV 660 Continuous T 44 T 24 T 35
T 21 /system/1/assets/files/000/000/380/380/06feaa7b3/original/TF015.WAV 800 Continuous – IMO code 2 (High) T 44 T 24 T 35
T 22 /system/1/assets/files/000/000/406/406/49b88184e/original/TF043.WAV 1200 Continuous T 44 T 24 T 35
T 23 /system/1/assets/files/000/000/407/407/ecce63f4f/original/TF038.WAV 2000 Continuous T 15 T 3 T 35
T 24 /system/1/assets/files/000/000/421/421/b578af8a9/original/TF005.WAV 2400 Continuous T 48 T 20 T 35
T 25 /system/1/assets/files/000/000/951/951/d9ce2b2c6/original/TF062.wav 440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent T 1 T 44 T 8
T 26 /system/1/assets/files/000/000/954/954/b703d99f1/original/TF063.wav 470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent T 1 T 44 T 8
T 27 /system/1/assets/files/000/000/955/955/0f602886a/original/TF064.wav 470 @ 5Hz (0.10s on, 0.10s off) Intermittent T 1 T 44 T 8
T 28 /system/1/assets/files/000/000/956/956/dbb5f64db/original/TF065.wav 544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent T 44 T 24 T 8
T 29 /system/1/assets/files/000/000/957/957/7bd3d8c1c/original/TF066.wav 655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent T 1 T 44 T 8
T 30 /system/1/assets/files/000/000/397/397/d6d84d0c3/original/TF018.WAV 660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent T 44 T 24 T 8
T 31 /system/1/assets/files/000/000/381/381/93f51c79a/original/TF016.WAV 660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent T 30 T 24 T 8
T 32 /system/1/assets/files/000/000/410/410/a0f0ba2a6/original/TF033.WAV 745 @ 1Hz (0.50s on, 0.50s off) Intermittent T 44 T 24 T 8
T 33 /system/1/assets/files/000/000/379/379/51c1bb5a9/original/TF014.WAV 800 (0.25s on, 1.00s off) Intermittent T 53 T 24 T 8
T 34 /system/1/assets/files/000/000/388/388/b4cf9203e/original/TF023.WAV 800 @ 2Hz (0.25s on, 0.25s off) – IMO code 3.a (High) T 56 T 24 T 8
T 35 /system/1/assets/files/000/000/377/377/ac5498db0/original/TF011.WAV 1000 @ 1Hz (0.50s on, 0.50s off) Intermittent T 44 T 24 T 8
T 36 /system/1/assets/files/000/000/378/378/6380218ec/original/TF013.WAV 2400 @ 1Hz (0.50s on, 0.50s off) Intermittent T 21 T 24 T 8
T 37 /system/1/assets/files/000/000/958/958/a90e62da4/original/TF067.wav 2900 @ 5Hz (0.10s on, 0.10s off) Intermittent T 53 T 24 T 8
T 38 /system/1/assets/files/000/000/959/959/f34b52faa/original/TF068.wav 363/518 @ 1Hz (0.50s / 0.50s) Alternating T 1 T 8 T 19
T 39 /system/1/assets/files/000/000/960/960/368703340/original/TF069.wav 450/500 @ 2Hz (0.25s / 0.25s) Alternating T 1 T 8 T 19
T 40 /system/1/assets/files/000/000/385/385/a85a0a356/original/TF021.WAV 554/440 @ 1Hz (0.50s / 0.50s) Alternating T 44 T 24 T 19
T 41 /system/1/assets/files/000/000/961/961/be2680966/original/TF070.wav 554/440 @ 0.65Hz (0.76s / 0.76s) Alternating T 1 T 8 T 19
T 42 /system/1/assets/files/000/000/962/962/314fe8a1b/original/TF071.wav 561/760 @ 0.83Hz (0.60s / 0.60s) Alternating T 1 T 8 T 19
T 43 /system/1/assets/files/000/000/963/963/5f6deb8a1/original/TF072.wav 780/600 @ 0.96Hz (0.52s / 0.52s) Alternating T 1 T 8 T 19
T 44 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 800/1000 @ 2Hz (0.25s / 0.25s) Alternating T 5 T 24 T 19
T 45 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 970/800 @ 2Hz (0.25s / 0.25s) Alternating T 1 T 8 T 19
T 46 /system/1/assets/files/000/000/375/375/771bd7a3e/original/TF012.WAV 800/1000 @ 0.875Hz (0.57s / 0.57s) Alternating T 53 T 24 T 19
T 47 /system/1/assets/files/000/000/374/374/021ee6540/original/TF010.WAV 2400/2900 @ 2Hz (0.25s / 0.25s) Alternating T 57 T 24 T 19
T 48 /system/1/assets/files/000/000/965/965/e3d76c24c/original/TF073.wav 500/1200 @ 0.3Hz (1.67s / 1.67s) Sweeping T 44 T 24 T 12
T 49 /system/1/assets/files/000/000/964/964/4e1cd3f7f/original/TF074.wav 560/1055 @ 0.18Hz (2.73s / 2.73s) Sweeping T 44 T 24 T 12
T 50 /system/1/assets/files/000/000/966/966/a8e5f4440/original/TF075.wav 560/1055 @ 3.3Hz (0.15s / 0.15s) Sweeping T 44 T 24 T 12
T 51 /system/1/assets/files/000/000/969/969/5734194b1/original/TF076.wav 600/1250 @ 0.125Hz (4s / 4s) Sweeping T 44 T 24 T 12
T 52 /system/1/assets/files/000/000/394/394/1bfee2f1b/original/TF031.WAV 660/1200 @ 1Hz (0.50s / 0.50s) Sweeping T 64 T 24 T 12
T 53 /system/1/assets/files/000/000/420/420/50f9ee7a7/original/TF004.WAV 800/1000 @ 1Hz (0.50s / 0.50s) Sweeping T 56 T 24 T 12
T 54 /system/1/assets/files/000/000/392/392/68d5d1294/original/TF029.WAV 800/1000 @ 7Hz (0.07s / 0.07s) Sweeping T 57 T 24 T 12
T 55 /system/1/assets/files/000/000/389/389/68683d240/original/TF024.WAV 800/1000 @ 50Hz (0.01s / 0.01s) Sweeping T 54 T 24 T 12
T 56 /system/1/assets/files/000/000/422/422/42b72dd93/original/TF006.WAV 2400/2900 @ 7Hz (0.07s / 0.07s) Sweeping T 57 T 24 T 12
T 57 /system/1/assets/files/000/000/373/373/a686b0abe/original/TF007.WAV 2400/2900 @ 1Hz (0.50s / 0.50s) Sweeping T 47 T 24 T 12
T 58 /system/1/assets/files/000/000/398/398/7c1bf5e00/original/TF025.WAV 2400/2900 @ 50Hz (0.01s / 0.01s) Sweeping T 54 T 24 T 12
T 59 /system/1/assets/files/000/000/967/967/2e92dbc46/original/TF077.wav 2500/3000 @ 2Hz (0.25s / 0.25s) Sweeping T 44 T 24 T 12
T 60 /system/1/assets/files/000/000/968/968/5dfcb9aea/original/TF078.wav 2500/3000 @ 7.7Hz (0.65s / 0.65s) Sweeping T 44 T 24 T 12
T 61 /system/1/assets/files/000/000/408/408/e0fadcdd2/original/TF042.WAV 800Hz Motor Siren T 44 T 24 T 12
T 62 /system/1/assets/files/000/000/404/404/1c1741943/original/TF041.WAV 1200Hz Motor Siren T 44 T 24 T 12
T 63 /system/1/assets/files/000/000/409/409/590aa5e82/original/TF044.WAV 2400Hz Motor Siren T 44 T 24 T 12
T 64 /system/1/assets/files/000/000/395/395/631e82dc8/original/TF026.WAV Simulated Bell T 44 T 21 T 12
Country specific or custom tone configurations and alarm frequencies are available upon request.

Upcoming Events

Intersec logo %28png%29
Adipec 2025 logo   0224
Fse (4)
Nfpa conference expo