Datasheet | Datasheet.pdf |
Installation Manual | D199-00-201-IS_Issue_2_STExB2X10_15_.pdf |
Installation Manual - Russia | D199-00-201-IS-RUS_Issue_1.pdf |
INMETRO Installation Manual | D199-00-201-IS-IEx_Issue_A.pdf |
IECEx certificate | IECEx_ULD_16.0017X_Issue_1_STEx.pdf |
ATEX certificate | DEMKO_16_ATEX_1466X_Issue_1_STEx.pdf |
INMETRO certificate | CoC_IEx_20.0156X_Rev_0_STEx.pdf |
Russian Ex certificate | __RU_C_GB.71.B.00109.pdf |
DNV Type Approval | TAA00001JN_1.pdf |
Declaration of Conformity | DC-070_Issue_F_STEx.pdf |
SIL1 Certificate | T900-123-1_Beacons_SIL1.pdf |
2D drawing (PDF) | SK0392_Issue_A.pdf |
2D drawing (DWG) | SK0392_Issue_A.DWG |
3D drawing (IGS) | SK0392-3D_Issue_A.IGS |
3D drawing (STEP) | SK0392-3D_Issue_A.STEP |
Wiring Schematic | D199-06-201_Issue_B__STExB2X10_15_.pdf |
Pipe Mount Drawing (PDF) | D217-05-281_Issue_B_STExB2.pdf |
Energy: | 15 Joules (15Ws) |
Flash rate: | 1Hz (60 fpm), 1.5Hz (90fpm) & double flash |
Peak Candela: | 1,500,000 cd – calculated from energy (J) |
Eff. Intensity cd: | 750 cd – calculated from energy (J) |
Peak Candela: | 114,854 cd – measured ref to I.E.S |
Eff. Intensity cd: | 666.92 cd – measured ref to I.E.S |
Lens colours: | Amber, Blue, Clear, Green, Magenta, Red & Yellow |
Voltages DC: | 24vdc; 48Vdc |
Voltages AC: | 115Vac; 230Vac |
Ingress protection: | EN60529: IP66 |
Enclosure matl: | 316L Stainless Steel |
Enclosure finish: | Chromated & powder coated |
Colour: | RAL3000 Red |
Cable entries: | 4 x M20 ISO (3 x stopping plugs included as standard) Adaptors to M25, 1/2" & 3/4" NPT can be specified |
Terminals: | 0.5 – 2.5mm² (20-14 AWG) |
Enclosure volume: | <2 litres |
Line monitoring: | Blocking diode included EOL Min. 500 Ohm 2w, or 3k3 Ohm 0.5w resistor or diode (DC versions) can be fitted |
Grounding stud: | M5 |
Tube life: | Emissions are reduced to 70% after 8 million flashes |
Temperature range: | -50° to +70°C (-58°F to +158°F) |
Relative humidity: | 95% – Additional tropicalisation is recommended for applications where both high relative humidity and high ambient temperatures exist |
Weight: | 6.0kg/13.23lbs |
*All candela data is representative of performance with clear lens at optimum voltage. | |
Example part code: | STExB2X15AC230 [e][m][s][v][x]/[y] STExB2X15AC230AS2A1R/R STExB2X15 15 Joule Xenon Strobe Beacon, 230V ac, 4 x M20 entries, Stainless Steel stopping plugs, A4 316 SS dome guard, IECEx & ATEX approved, Red enclosure, Red lens |
Version: | In Rush: | Voltage: | Current: |
---|---|---|---|
24V dc | 0.7A 6.8ms | 20-28V dc | 822mA |
48V dc | 42-54V dc | 342mA | |
115V ac | 110-125V ac 50/60Hz | 328mA | |
230V ac | 220-240V ac 50/60Hz | 168mA |
Version: | Part code: | ||
---|---|---|---|
Product type: | STExB2 | ||
Type: | X15 | Xenon Beacon – 15 Joule | |
Voltage: | DC024 DC048 AC115 AC230 |
20-28V dc 42-54V dc 115V ac +/-10% 230V ac +/-10% |
|
Cable Entry Type:[e] | A B C D E F G H I J |
4 x M20x1.5mm 2 × 1/2" NPT – adaptors 2 × 3/4" NPT – adaptors 2 x M25x1.5mm – adaptors 1 × 1/2" NPT – adaptor 1 × 3/4" NPT – adaptor 1 x M25x1.5mm – adaptor 3 × 1/2" NPT – adaptors 3 × 3/4" NPT – adaptors 3 x M25x1.5mm – adaptors |
|
Adaptor/Stopping plug material: [m] |
B N S |
Brass Nickel Plated Stainless Steel (standard) |
|
Guard material & tag: [s] | 1 2 3 4 |
A2 304 Stainless Steel A4 316 Stainless Steel (default) A2 304 St/St with Equip. Tag A4 316 St/St with Equip. Tag |
|
Product version: [v] | A1 M1 |
IECEx & ATEX Group II 2G/D Zone 1, 2, 21 & 22 IECEx & ATEX Group II 2G/D Zone 1, 2, 21 & 22 & DNV Type Approval |
|
Enclosure colour: [x] | R S |
Red Special (contact E2S) |
|
Lens colour: [y] | A B C G M R Y |
Amber Blue Clear Green Magenta Red Yellow |
|
Accessories: | SP65-0001-A2 SP65-0001-A4 SP65-0003-A2 SP65-0003-A4 |
Pole Mount Bracket Kit 2" St/St A2 (304) Pole Mount Bracket Kit 2" St/St A4 (316) Sunshade – St/St A2 (304) Sunshade – St/St A4 (316) |
Amber | Blue | Clear | Green | Red | Yellow |
0.70 | 0.24 | 1.00 | 0.25 | 0.23 | 0.93 |