Product finder
Product code
Application
Environment
Device
Category
Product
Type
Product finder

Find the right E2S product

Search

D1xS2H 128dB(A) Alarm Horn Sounder 1-22-155

Product Image
Product Image
Product Image
The D1xS2H alarm horn sounder has a sound output of up to 128dB(A) – a class leading, high performance globally certified audible notification signal. The robust Type 4/4X, IP66 marine grade, corrosion proof aluminium enclosure is approved for Class I & II Div 1, Zone 1 & 20, IECEx and ATEX Zone 1, 2, 21 & 22 explosion proof signalling applications.
Request a quote for this product
Voltage
Cable entries
Stopping plug/adaptor material
Bracket material
Product version
Product option
Enclosure colour
Part Number:
D1xS2H
Request Price or enquire about this product
Enquire about
128dB(A) Alarm Horn Sounder

New Product

  • Max 127dB(A) @ 1m sound pressure level
  • New high output horn design
  • New D Class amplifier technology
  • Low in-rush
  • A4 316 stainless steel bracket as standard
  • Tropicalised electronics
  • New stage activation and line monitoring capability

Description

Featuring 64 alarm tones, each of the 4 stage/channels can be remotely activated. Class D amplification provides a high sound output with a choice of two power modes. The threaded flameproof joint, multiple cable entries and duplicated, pluggable termination simplifies both installation and routine maintenance. The 24Vdc version is approved for public mode fire alarm use and the 100-240Vac version for general signalling use. SIL1 & SIL2 Route 2H compliant to IEC61508 (2010) as standard.

Downloads

Datasheet Datasheet.pdf
Install manual: Product version [A] D190-01-101-IS_Issue_4__D1xS2-A_.pdf
Install manual: Product version [S] D190-01-671-IS_Issue_2__D1xS2-S_.pdf
Install manual: Product version [D] D190-01-151-IS_Issue_2__D1xS2-D_.pdf
IECEx certificate IECEx_ULD_19.0008X_002_D1xC_S_L.pdf
ATEX certificate DEMKO_19_ATEX_2141X_Issue_2_D1xC_S_L.pdf
UL certificate of compliance UL_CoC_20150818-E230764_Vol1Sec3__D1xS-C_.pdf
CSFM Listing CSFM_Listing_2279-0506_D1xS__D1xC_2024.pdf
UKCA Certificate UL21UKE2132X_Rev1_D1xC_S_L.pdf
CCOE PESO COOE_P576154_D1xS_D1xC_D1xL.pdf
ECAS Ex Approval ECAS_23-08-81417_E23-07-082239_NB0007_D1xS-L.pdf
Ingress Protection certificate TL23065B_E2S_IP66_and_IPX7.pdf
Declaration of Conformity DC-067_Issue_H__D1x_.pdf
Declaration of Conformity UKCA DC-097_Issue_A__D1x_UKCA_.pdf
SIL Certificate: Product version [A] T1072-215-2_SIL2_SIL1_2H__D1xS_D1xC_STExS_STExC_GNExS_A112N_AL112N_A121_AL121_MA_.pdf
2D drawing (PDF) D190-05-121_Issue_B.pdf
2D drawing (DWG) D190-05-121_Issue_B.dwg
3D drawing (STEP) D190-05-121-3D_Issue_1.STEP
Wiring Schematic DC voltage D190-06-001_Issue_1.pdf
Wiring Schematic AC voltage D190-06-005_Issue_1.pdf
Nameplate Drawing D190-09-101_Issue_1.pdf
Equipment Tag Drawing D254-00-101_Issue_1.pdf
Duty Label Drawing D254-00-001_Issue_1.pdf
Pole Mount & Sun Shade Drawing D217-05-062_Issue_2__D1x_D2x_S2H_L2H_.pdf

Features

  • Maximum sound pressure level output of 128dB(A)
  • Choice of 64 alarm tone frequencies
  • 4 remotely selectable alarm stages/channels
  • Positive or negative line stage/channel switching
  • Automatic synchronisation on multi-sounder system
  • Stainless Steel mounting bracket included as standard
  • Triple cable entries
  • Available with custom tone configurations and frequencies
  • Robust marine grade aluminium enclosure
  • UL464 Public mode fire alarm use
  • CAN/ULC S525 Audible Signaling Devices for Fire Alarm

Specification

Maximum output: High power level: 128dB(A) @ 1 m +/- 3dB
[119dB(A) @ 10ft/3m +/- 3dB]
Medium power level: 125dB(A) @ 1 m +/- 3dB
[118dB(A) @ 10ft/3m +/- 3dB]
Class II Product version: D -15dB(A)
Nominal output: High power level: 126dB(A) @ 1m +/- 3dB
[117dB(A) @ 10ft/3m] +/- 3dB
Medium power level: 122dB(A) @ 1m +/- 3dB
[113dB(A) @ 10ft/3m] +/- 3dB
Class II Product version: D -15dB(A)
No. of tones: 64 (UKOOA / PFEER compliant)
No. of stages: 4
Volume control: Full range
Effective range: >350m/1148ft @ 1KHz
Voltages DC: 24Vdc (11.5-54Vdc)
Voltages AC: 230Vac (100-240Vac)
In-rush: 815mA within 4ms @ 24Vdc
Stage switching: DC units: positive or negative
AC units: common supply line
Safety Integrity Level: SIL1 and SIL2 Route 2H IEC61508 (2010)
Ingress protection: EN60529: IP66/67
UL50E / NEMA250: 4 / 4X / 3R / 13
Enclosure material: Marine grade LM6 aluminium alloy
Enclosure colour: Red or Grey, custom colours available on request
Enclosure finish: Chromate & powder coated finish
Cable entries: 1×1/2"NPT & 2xM20
Thread adaptors available
Stopping plugs: Brass, Nickel Plated or Stainless Steel
Terminals: 0.5 – 2.5mm² (20-14AWG) – 12AWG solid core conductor
Pluggable & duplicated terminals
Line monitoring: Blocking diode included
EOL Min. 500 Ohm 2W, or 3k3 Ohm 0.5W resistor
or diode (DC versions) can be fitted
Ground/Earth stud: M5
Enclosure volume: <2 litres
Installation temp: -55 to +85°C [-67° to +185°F]
Storage temp: -55 to +85°C [-67° to +185°F]
Relative humidity: 99%
Vibration test: 35Hz for a duration 4Hr (UL464)
Jarring test: 3ft/lb Energy (UL464)
Impact test: 3x 5lb (UL464)
MTBF DC: 225.16 years / 1,972,386 hours – MIL 217
MTBF AC: 138.96 years / 1,217,285 hours – MIL 217
Weight: 4.6kg/10.1lbs

Current Consumption

Nominal
Voltage:
Voltage
range:
Medium Power
current:
Medium Power Max.
Current:
High Power
current:
High Power Max.
Current:
In-rush:
12Vdc 11.5-54Vdc 289mA 324mA 356mA 740mA 815mA <4ms
24Vdc 11.5-54Vdc 324mA 324mA 740mA 740mA 815mA <4ms
48Vdc 11.5-54Vdc 195mA 324mA 391mA 740mA 815mA <4ms
115Vac 50/60Hz 100-240V ac 125mA 138mA 282mA 325mA -
230Vac 50/60Hz 100-240V ac 78mA 138mA 167mA 325mA -

Part Codes

Part Code: Identifier: Description:
Product type: D1xS2 D1xS2 alarm horn sounder
Horn type: H High SPL flare re-entrant horn
Voltage: DC024
AC230
11.5-54Vdc
100-240Vac
Cable entries:[e] A
B
C
D
F
G
Note:
2 x M20x1.5mm & 1 × 1/2"NPT
2 × 1/2"NPT – adaptors
2 × 3/4"NPT – adaptors
2 x M25x1.5mm – adaptors
1 × 3/4"NPT – adaptor
1 x M25x1.5mm – adaptor
All entries, excluding thread adaptors, supplied with stopping plugs installed.
Stopping plug/
adaptor material: [m]
B
N
S
Brass
Nickel plated brass
Stainless steel
Bracket material: [s] 1
3
5
A4 316 Stainless Steel
A4 316 St/St with Equip. Tag
A4 316 St/St with Equip. Tag and Duty Label
Product version: [v] A
D
S
UL, cUL, ULC, IECEx, ATEX – SIL1 & SIL2 Route 2H
Class II – UL, cUL
UL, cUL, ULC, IECEx, ATEX – SIL2
Route 1H with diagnostics SFF: >99%
Product option:
[o]
1
Z
X
Y
K
V
Standard product
Custom alarm tone software – contact E2S
Custom configuration – contact E2S
Stage control Config. 4
Stage control Config. 5 (DC) and Config. 2 (AC)
Stage control Config. 6
Enclosure colour: [x] R
G
S
Red
Grey
Special colour – contact E2S
Accessories:
SP65-0001-A4 Pole Mount Bracket Kit St/St A4 (316)
Alarm stage control:
Please review the installation manual and wiring schematics for remote stage control and EOL resistor monitoring configuration options:
Config. 1 [DC]: Factory default. Common negative, positive switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 2 [DC]: User setting. Common positive, negative switching. Up to 4 Alarm Stages. EOL monitoring Alarm Stage 1 only
Config. 3 [DC]: User setting. Common negative, positive switching activation of Alarm Stages 1 & 2 with EOL on both stages. Reverse polarity monitoring
Config. 4 [DC]: Product option ‘Y’. Independent activation of Alarm Stages 1 & 2 with EOL on both stages. Forward polarity monitoring
Config. 5 [DC]: Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages
Config. 6 [DC]: Product option ‘V’. Independent activation of up to 4 Alarm Stages with EOL on all stages. Forward polarity monitoring
Config. 1 [AC]: Factory default. Up to 4 Alarm Stages. Stage 1 activated at power on. Stages 2, 3 and 4 via volt free contacts
Config. 2 [AC]: Product option ‘K’. Horn continuously powered. Voltage free activation of up to 3 alarm stages

Approvals

  • UL/cUL/ULC File ref: E230764
  • IECEx Certificate: IECEx ULD 19.0008X
  • ATEX Certificate: DEMKO 19 ATEX 2141X
  • CSFM listing: 7136-2279:0506
  • UKCA certificate: UL21UKEX2132X
  • SIL1 & SIL2 compliant to IEC61508 (2010)

Coding

  • NEC / CEC Class / Zone
    Class I Zone 1 IIC T4A Ta -55°C to +85°C
    Class I Zone 1 IIC T5 Ta -55°C to +75°C (T6 +65°C)
  • NEC / CEC Class / Div
    Class I Div 1 ABCD T4A Ta -55°C to +85°C
    Class I Div 1 ABCD T5 Ta -55°C to +80°C (T6 +65°C)
  • IECEx / ATEX
    II 2G Ex db IIC T5 Gb Ta -55°C to +75°C
    II 2G Ex db IIC T6 Gb Ta -55°C to +60°C
    II 2D Ex tb IIIC T93°C Db Ta ‐55°C to +75°C
  • Product version: D
  • NEC / CEC Class / Zone
    Zone 20 IIIB Ta -55°C to +70°C
  • NEC / CEC Class / Div
    Class II Div 1 FG T6 Ta -55°C to +70°C
    Class III Div 1 Ta -55°C to +70°C
    See product manual for full voltage specific coding.

Tone Table

Stage 1 WAV file Frequency Description. Stage 2 Stage 3 Stage 4
T 1 /system/1/assets/files/000/000/405/405/214ccf82a/original/TF037.WAV 1000 Continuous – PFEER Toxic Gas Any T 2 T 44
T 2 /system/1/assets/files/000/000/386/386/ceb4e488c/original/TF009.WAV 1200/500 @ 1Hz Sweeping – DIN / PFEER P.T.A.P. Any T 3 T 44
T 3 /system/1/assets/files/000/000/412/412/fa8b418f9/original/TF045.WAV 1000 @ 0.5Hz (1s on, 1s off) Intermittent – PFEER Gen. Alarm Any T 2 T 44
T 4 /system/1/assets/files/000/000/383/383/11797b764/original/TF019.WAV 1.4KH-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s – NF C 48-265 Any T 24 T 1
T 5 /system/1/assets/files/000/000/382/382/2c2978b6a/original/TF017.WAV 544(100mS)/440 (400mS) – NF S 32-001 Any T 19 T 1
T 6 /system/1/assets/files/000/000/947/947/8f040484a/original/TF053.wav 1500/500 – (0.5s on , 0.5s off) x3 + 1s gap – AS4428 Any T 44 T 1
T 7 /system/1/assets/files/000/000/944/944/890010fd0/original/TF054.wav 500-1500Hz Sweeping 2 sec on 1 sec off – AS4428 Any T 44 T 1
T 8 /system/1/assets/files/000/000/417/417/abf396de0/original/TF003.WAV 500/1200Hz @ 0.26Hz(3.3s on, 0.5s off) – NEN 2575 Any T 24 T 35
T 9 /system/1/assets/files/000/000/953/953/5deedc543/original/TF055.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 10 /system/1/assets/files/000/000/952/952/3a041fde3/original/TF056.wav 1000 (1s on, 1s off)x7 + (7s on, 1s off) – IMO Code 1a Any T 34 T 1
T 11 /system/1/assets/files/000/000/946/946/761de34c6/original/TF057.wav 420(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal Any T 1 T 8
T 12 /system/1/assets/files/000/000/945/945/689d9405a/original/TF058.wav 1000(0.5s on, 0.5s off)x3 + 1s gap – ISO 8201 Temporal Any T 1 T 8
T 13 /system/1/assets/files/000/000/950/950/2d337d14e/original/TF059.wav 422/775 – (0.85 on, 0.5 off) x3 + 1s gap – NFPA Temporal Any T 1 T 8
T 14 /system/1/assets/files/000/000/399/399/84b54dafb/original/TF034.WAV 1000/2000 @ 1Hz – Singapore Any T 3 T 35
T 15 /system/1/assets/files/000/000/393/393/744c6f53f/original/TF030.WAV 300 Continuous Any T 24 T 35
T 16 /system/1/assets/files/000/000/391/391/5f7a58b54/original/TF028.WAV 440 Continuous Any T 24 T 35
T 17 /system/1/assets/files/000/000/948/948/c697b364a/original/TF060.wav 470 Continuous Any T 24 T 35
T 18 /system/1/assets/files/000/000/949/949/7e429e658/original/TF061.wav 500 Continuous – IMO code 2 (Low) Any T 24 T 35
T 19 /system/1/assets/files/000/000/390/390/10abe0caa/original/TF027.WAV 554 Continuous Any T 24 T 35
T 20 /system/1/assets/files/000/000/384/384/5c30f9f4d/original/TF020.WAV 660 Continuous Any T 24 T 35
T 21 /system/1/assets/files/000/000/380/380/06feaa7b3/original/TF015.WAV 800 Continuous – IMO code 2 (High) Any T 24 T 35
T 22 /system/1/assets/files/000/000/406/406/49b88184e/original/TF043.WAV 1200 Continuous Any T 24 T 35
T 23 /system/1/assets/files/000/000/407/407/ecce63f4f/original/TF038.WAV 2000 Continuous Any T 3 T 35
T 24 /system/1/assets/files/000/000/421/421/b578af8a9/original/TF005.WAV 2400 Continuous Any T 20 T 35
T 25 /system/1/assets/files/000/000/951/951/d9ce2b2c6/original/TF062.wav 440 @ 0.83Hz (0.60s on, 0.60s off) Intermittent Any T 44 T 8
T 26 /system/1/assets/files/000/000/954/954/b703d99f1/original/TF063.wav 470 @ 0.9Hz (0.55s on, 0.55s off) Intermittent Any T 44 T 8
T 27 /system/1/assets/files/000/000/955/955/0f602886a/original/TF064.wav 470 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T 44 T 8
T 28 /system/1/assets/files/000/000/956/956/dbb5f64db/original/TF065.wav 544 @ 1.14Hz (0.43s on, 0.44s off) Intermittent Any T 24 T 8
T 29 /system/1/assets/files/000/000/957/957/7bd3d8c1c/original/TF066.wav 655 @ 0.875Hz (0.57s on, 0.57s off) Intermittent Any T 44 T 8
T 30 /system/1/assets/files/000/000/397/397/d6d84d0c3/original/TF018.WAV 660 @ 0.28Hz (1.80s on, 1.80s off) Intermittent Any T 24 T 8
T 31 /system/1/assets/files/000/000/381/381/93f51c79a/original/TF016.WAV 660 @ 3.3Hz (0.15s on, 0.15s off) Intermittent Any T 24 T 8
T 32 /system/1/assets/files/000/000/410/410/a0f0ba2a6/original/TF033.WAV 745 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 33 /system/1/assets/files/000/000/379/379/51c1bb5a9/original/TF014.WAV 800 (0.25s on, 1.00s off) Intermittent Any T 24 T 8
T 34 /system/1/assets/files/000/000/388/388/b4cf9203e/original/TF023.WAV 800 @ 2Hz (0.25s on, 0.25s off) – IMO code 3.a (High) Any T 24 T 8
T 35 /system/1/assets/files/000/000/377/377/ac5498db0/original/TF011.WAV 1000 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 36 /system/1/assets/files/000/000/378/378/6380218ec/original/TF013.WAV 2400 @ 1Hz (0.50s on, 0.50s off) Intermittent Any T 24 T 8
T 37 /system/1/assets/files/000/000/958/958/a90e62da4/original/TF067.wav 2900 @ 5Hz (0.10s on, 0.10s off) Intermittent Any T 24 T 8
T 38 /system/1/assets/files/000/000/959/959/f34b52faa/original/TF068.wav 363/518 @ 1Hz (0.50s / 0.50s) Alternating Any T 8 T 19
T 39 /system/1/assets/files/000/000/960/960/368703340/original/TF069.wav 450/500 @ 2Hz (0.25s / 0.25s) Alternating Any T 8 T 19
T 40 /system/1/assets/files/000/000/385/385/a85a0a356/original/TF021.WAV 554/440 @ 1Hz (0.50s / 0.50s) Alternating Any T 24 T 19
T 41 /system/1/assets/files/000/000/961/961/be2680966/original/TF070.wav 554/440 @ 0.65Hz (0.76s / 0.76s) Alternating Any T 8 T 19
T 42 /system/1/assets/files/000/000/962/962/314fe8a1b/original/TF071.wav 561/760 @ 0.83Hz (0.60s / 0.60s) Alternating Any T 8 T 19
T 43 /system/1/assets/files/000/000/963/963/5f6deb8a1/original/TF072.wav 780/600 @ 0.96Hz (0.52s / 0.52s) Alternating Any T 8 T 19
T 44 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 800/1000 @ 2Hz (0.25s / 0.25s) Alternating Any T 24 T 19
T 45 /system/1/assets/files/000/000/419/419/e353c86c4/original/TF002.WAV 970/800 @ 2Hz (0.25s / 0.25s) Alternating Any T 8 T 19
T 46 /system/1/assets/files/000/000/375/375/771bd7a3e/original/TF012.WAV 800/1000 @ 0.875Hz (0.57s / 0.57s) Alternating Any T 24 T 19
T 47 /system/1/assets/files/000/000/374/374/021ee6540/original/TF010.WAV 2400/2900 @ 2Hz (0.25s / 0.25s) Alternating Any T 24 T 19
T 48 /system/1/assets/files/000/000/965/965/e3d76c24c/original/TF073.wav 500/1200 @ 0.3Hz (1.67s / 1.67s) Sweeping Any T 24 T 12
T 49 /system/1/assets/files/000/000/964/964/4e1cd3f7f/original/TF074.wav 560/1055 @ 0.18Hz (2.73s / 2.73s) Sweeping Any T 24 T 12
T 50 /system/1/assets/files/000/000/966/966/a8e5f4440/original/TF075.wav 560/1055 @ 3.3Hz (0.15s / 0.15s) Sweeping Any T 24 T 12
T 51 /system/1/assets/files/000/000/969/969/5734194b1/original/TF076.wav 600/1250 @ 0.125Hz (4s / 4s) Sweeping Any T 24 T 12
T 52 /system/1/assets/files/000/000/394/394/1bfee2f1b/original/TF031.WAV 660/1200 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 53 /system/1/assets/files/000/000/420/420/50f9ee7a7/original/TF004.WAV 800/1000 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 54 /system/1/assets/files/000/000/392/392/68d5d1294/original/TF029.WAV 800/1000 @ 7Hz (0.07s / 0.07s) Sweeping Any T 24 T 12
T 55 /system/1/assets/files/000/000/389/389/68683d240/original/TF024.WAV 800/1000 @ 50Hz (0.01s / 0.01s) Sweeping Any T 24 T 12
T 56 /system/1/assets/files/000/000/422/422/42b72dd93/original/TF006.WAV 2400/2900 @ 7Hz (0.07s / 0.07s) Sweeping Any T 24 T 12
T 57 /system/1/assets/files/000/000/373/373/a686b0abe/original/TF007.WAV 2400/2900 @ 1Hz (0.50s / 0.50s) Sweeping Any T 24 T 12
T 58 /system/1/assets/files/000/000/398/398/7c1bf5e00/original/TF025.WAV 2400/2900 @ 50Hz (0.01s / 0.01s) Sweeping Any T 24 T 12
T 59 /system/1/assets/files/000/000/967/967/2e92dbc46/original/TF077.wav 2500/3000 @ 2Hz (0.25s / 0.25s) Sweeping Any T 24 T 12
T 60 /system/1/assets/files/000/000/968/968/5dfcb9aea/original/TF078.wav 2500/3000 @ 7.7Hz (0.65s / 0.65s) Sweeping Any T 24 T 12
T 61 /system/1/assets/files/000/000/408/408/e0fadcdd2/original/TF042.WAV 800Hz Motor Siren Any T 24 T 12
T 62 /system/1/assets/files/000/000/404/404/1c1741943/original/TF041.WAV 1200Hz Motor Siren Any T 24 T 12
T 63 /system/1/assets/files/000/000/409/409/590aa5e82/original/TF044.WAV 2400Hz Motor Siren Any T 24 T 12
T 64 /system/1/assets/files/000/000/395/395/631e82dc8/original/TF026.WAV Simulated Bell Any T 21 T 12
For Stage 2 any Stage 1 alarm tone sound can be selected.
Country specific or custom tone configurations and alarm frequencies are available upon request.

Upcoming Events

Fse (4)
Cafaa%202020%20final%20cmyk
Logo
Nfpa conference expo